VBAPV & VBAPV-K PVC INSULATED, SCREENED INDOOR TYPE TELEPHONE CABLES
Marking
BIRTAS KABLO VBVAPV-K 100 x 2 x 0.50+0.50mm 1406 02 100 TS 2814 Part no GOST-R CE....mt
Applications
These cables are used as telephone cables inside the buildings for signal transmision and subscriber distribution purposes. VBAPV-K has tinned copper conductor which this cable is used especially at humudity places. And also screen provides protection against external pulses .Additionally these cables are suitable for applications at small bending radius.
Cable Design
Conductor
Annealed copper conductor, solid; for VBAPV Tinned copper conductor, solid; for VBAPV-K
Insulation
PVC compound , IEC 60189-2
Core identification
According to IEC 60189-2
Pair
2 cores twisted to a pair, in different lay-length
Lay-up
Cables up to (included) 10 pairs laid up in layers. 20-100 pairs , are formed with 10 pairs subgroups