Halogen Free Data Cables
LIHH
LIHH-PF
LIHCH
LIHCH-PF
LIH(St)H
LIH(St)H-PF
LIH(St)CH
LIH(St)CH-PF
LIH(St)H-PIMF
LIH(St)CH-PIMF
LI2Y(St)CH-PIMF
JE-LIHCH…Bd Z
JE-H(St)H…Bd Z
CAT5e - HF
CAT6 - HF
Product Download Files
Birtaş Kablo - Kumanda Kabloları 2YSLCY-J
Product Data Sheet
Local Quality Certificates
International Quality Certificates
Product Price List
Test Reports
Package Style
Summary Table
Reference Samples
ISTINYE PARK SHOPPING CENTER
KORUPARK SHOPPING CENTER
FORUM MERSİN SHOPPING CENTER
CEPA SHOPPING CENTER
KANYON SHOPPING CENTER
ISTANBUL TEKSTILKENT
HALOGEN FREE DATA CABLES
LIHH-PF
HALOGEN-FREE PAIRED DATA CABLES
Marking

BIRTAS KABLO LIHH-PF 12 x 2 x 0.22mm2 1902 02 012 [TSEK] Part no GOST-R CE … mt

Application

These halogen-free unscreened the flexible control and computer cables with twisted pairs (in pair form) are mainly used for the transmission of analogue and digital signals in processor-controlled equipment and instrumentation and control engineering where low current consumptions are required, e.g. in industrial electronics, computers, information and transmission systems, office machines and precision mechanics The pairs form with optimum pair and layer pitch prevent mutual interaction from neighbouring conductor circuits as well from adjacent external cables. These cables are used at schools, airpots, hospitals, etc. and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. These cables are not intended for outdoor or underground installation.

Cable Design
ConductorFlexible copper wires, plain;
IEC 60228 Class 5, TS/DIN EN 60228 Class 5
InsulationHFFR compound, HI2 , VDE 0207-23
Core identificationAccording to DIN 47100 or TS/DIN EN 50334
black cores with white numerals
PairTwo conductors twisted to a pair
Lay-upCores laid up in layers of optimum pitch
SeparatorPolyester tape
Outer sheathHFFR compound, HM2, VDE 0207-24
HFFR: Halogen-free flame retardant
Sheath colourRAL 7001,Grey
Technical Data
StandardVDE 0812 & VDE 0814 & VDE 0245
Insulation resistanceMin. 200 MΩ.km
Mutual CapacitanceMax. 120 nF/km
Inductance~ 0,70 Mh/km
Impedance~ 80 MΩ
Rated voltage0,14 mm2 : 350 V
≥0,25 mm2 : 500V
Test voltage0,14 mm2 : 1200 V
≥0,25 mm2 : 1500V
Temperature rangeFixed: - 30 oC ~ + 70 oC
Mobile: - 5 oC ~ + 50 oC
Min. bending radiusFixed: 6 x D
Mobile: 12 x D
Flame testIEC 60332-3 & TS/DIN EN 50266-2-4
Smoke density testIEC 61034-2 & TS/DIN EN 61034-2
Halogen-free properties testIEC60754-1/2 & TS/DIN EN 50267-2
Cross Section
Part-NumberNo. of Cores x
Cross Section (mm2)
Approx. Outer Diameter (mm)Copper Weight (Kg/km)Approx. Cable Weight (Kg/km)
1902 01 0022x2x0,144,65,428
1902 01 0033x2x0,145,28,033
1902 01 0044x2x0,145,710,743
1902 01 0055x2x0,146,413,450
1902 01 0077x2x0,147,118,860
1902 01 01010x2x0,148,126,985
1902 01 01212x2x0,148,832,3100
1902 01 02020x2x0,1411,154,0150
1902 02 0022x2x0,225,18,435
1902 02 0033x2x0,225,912,645
1902 02 0044x2x0,226,216,855
1902 02 0055x2x0,226,821,065
1902 02 0077x2x0,227,629,475
1902 02 01010x2x0,229,342,0105
1902 02 01212x2x0,2210,350,4130
1902 02 02020x2x0,2213,484,0215
1902 04 0022x2x0,345,812,745
1902 04 0033x2x0,346,819,155
1902 04 0044x2x0,347,425,470
1902 04 0055x2x0,348,331,790
1902 04 0077x2x0,349,844,4105
1902 04 01010x2x0,3411,663,4150
1902 04 01212x2x0,3412,876,0200
1902 04 02020x2x0,3416,2126,7335
1902 05 0022x2x0,506,218,750
1902 05 0033x2x0,507,528,170
1902 05 0044x2x0,508,037,485
1902 05 0055x2x0,508,746,7100
1902 05 0077x2x0,509,865,4130
1902 05 01010x2x0,5011,393,4195
1902 05 01212x2x0,5012,9112,1245
1902 05 02020x2x0,5018,2195,0420