background
TR  EN  DE  RU

Products

Back to products list
Birtaş Kablo
Halogen Free Installation & Energy Cables
H05Z-U & H07Z-U/R & H05Z/K & H07Z/K
H05Z1-U & H07Z1-U/R & H05Z1/K & H07Z1/K
H03Z1Z1-F 300/300 V & H05Z1Z1-F 300/500 V
NHMH
NHXMH
N2XH
N2XCH
NHXMH FE180
N2XH FE180
(N)2GH FE180
(N)2GH FE180 - FLEX
(N)HXH FE180 E30
(N)HXH FE180 E90
(N)HXCH FE180 – E30
(N)HXCH FE180 – E90
Cu/XLPE/LSZH/SWA/LSZH – MULTICORE – BS 6724
2XHRH
Product Download Files
Birtaş Kablo - Kumanda Kabloları 2YSLCY-J
Product Data Sheet
Local Quality Certificates
International Quality Certificates
Product Price List
Test Reports
Package Style
Summary Table
Reference Samples
ISTINYE PARK SHOPPING CENTER
KORUPARK SHOPPING CENTER
FORUM MERSİN SHOPPING CENTER
CEPA SHOPPING CENTER
KANYON SHOPPING CENTER
ISTANBUL TEKSTİLKENT
HALOGEN FREE INSTALLATION & ENERGY CABLES
N2XH
HALOGEN-FREE, ENERGY CABLES, 0,6/1 kV
Marking

BIRTAS KABLO N2XH 1 x 35 (rm) mm2 1988 52 001 Part no GOST-R CE … mt

Applications

These halogen-free cables are used as energy, utility and lighting cables in dry, moist and wet rooms, for permanent installation above, on, in and under beneath plaster and also for outdoor applications where lots of human life and material assets are to be protected in industrial constructions, schools, hospitals, shopping and cultural centers,energy plants, airports, metros . In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire.

Cable Design
ConductorCu wires,plain, solid-core, multi-stranded
IEC 60228 Cls. 1/2, TS/DIN EN 60228 Cls. 1/2
InsulationXLPE compound, 2XI1, VDE 0276-604
Core identificationAccording to TS HD 308 S2 & VDE 0293-308;
Note: Other core configurations manufactured upon request.
Lay-upCores laid up in layers of optimum pitch
FillerHFFR filler compound
Outer sheathHFFR compound, HM4, VDE 0276-604
HFFR: Halogen-free flame retardant
Sheath colourRAL 9005, Black
Technical Data
Temp. at conductor90 oC
Rated voltage0,6 / 1 kV
Test voltage4000 V
Temperature rangeFixed: - 30 oC ~ + 90 oC
Mobile: - 5 oC ~ + 50 oC
Min. bending radiusSıngle-core: 15 x D
Multi-core: 12 x D
Flame testIEC 60332-3 & TS/DIN EN 50266-2-4
Smoke density testIEC 61034-2 & TS/DIN EN 61034-2
Halogen-free properties testIEC60754-1/2 & TS/DIN EN 50267-2
StandardDIN VDE 0276-604 & TS HD 604 S1 DIN VDE 0276-627 ? TS HD 627 S1
Cross Section
Part-NumberNo. of Cores x
Cross Section (mm2)
Approx. Outer Diameter (mm)Copper Weight (Kg/km)Approx. Cable Weight (Kg/km)
1988 15 0022x1,5 re9,229125
1988 15 0033x1,5 re10,143145
1988 15 0044x1,5 re10,658175
1988 15 0055x1,5 re11,672215
1988 15 0077x1,5 re12,5101250
1988 15 01010x1,5 re15,5144360
1988 16 0022x2,5 re10,148160
1988 16 0033x2,5 re10,672190
1988 16 0044x2,5 re11,696225
1988 16 0055x2,5 re12,6120275
1988 16 0077x2,5 re13,8168330
1988 16 01010x2,5 re17,7240475
1988 17 0011x4 re6,33980
1988 18 0011x6 re7,158115
1988 19 0011x10 re8,196175
1988 17 0022x4 re11,177210
1988 20 0011x16 re9,5154245
1988 17 0033x4 re11,6115250
1988 18 0022x6 re12,1115265
1988 17 0044x4 re12,7154300
1988 18 0033x6 re12,7173320
1988 51 0011x25 rm10,2240345
1988 19 0022x10 re13,6192375
1988 17 0055x4 re13,1192385
1988 18 0044x6 re14,1230395
1988 52 0011x35 rm11,6336460
1988 19 0033x10 re14,7288460
1988 19 0044x10 re16,1384585
1988 20 2033x16re/10 re17,1557750
1988 20 0044x16 re18,2614840
1988 51 2033x25rm/16 re21,28741170
1988 51 0044x25 rm25,09601350
1988 52 2033x35rm/16 re23,211621485
1988 52 0044x35 rm28,113441815
Top 