J-Y(St)Y Lg PVC INSULATED, SCREENED INSTALLATION CABLE FOR COMMUNICATIONS
Marking
BIRTAS KABLO J-Y(St)Y ….lg FIREALARM 5 x 2 x 0.60mm 1408 03 005 Part no GOST-R CE....mt
Applications
These cables are used for signal and data communications as an fixed indoor installations. Screen provides protection against electromagnetic interferences. Additionally these cables are suitable for applications at small bending radius.
Cable Design
Conductor
Plain copper conductor, solid
Insulation
PVC compound , YI1; VDE 0207-4
Core identification
VDE 0815
Pair
Two conductors twisted to a pair
Lay-up
Pairs laid up in layers of optimum pitch * 2 pairs twisted as star-quad
Separator
Polyester tape
Screen
Tinned Cu drain wire under the AL-PES tape Drain wire; Phi: 0,40 mm ≤ 10 pairs Phi: 0,60 mm > 10 pairs
Outer sheath
PVC compound, YM1; VDE 0207-5
Sheath colour
RAL 7032,Grey
Technical Data
Conductor resistance
0,60 mm = 130 Ω/km
Insulation resistance
Min. 100 MΩ.km
Mutual Capacitance
Max. 100 nF/km * This value may be exceeded by 20% by cables with up to 4 pairs
Capacity Unbalanced
300 pF / 100 mt * 20% of the values, at least one value up to 500 pF permitted
Operating voltage, peak
Max. 300 V * up to 600V permissible for short periods (6 s/min)