SIHF EWKF
H05SS-F EWKF
SIMH-FR FE 180
SIMH-FR/PF FE 180
SIMH-SPEC
H05SC4S-K…(SIMH C1)
H05SSC4S-K…(SIMH C2)
SIMH-GL
SIMH-GLS (GLP)
H05SSQS-K…(SIMH-S)
LISHCSH FE 180–E30/E90
JE-SH(St)SH FE 180-E30/E90 …Bd Z
BUJI CABLE – 7 / 10 kV
BUJI CABLE – 16 / 20 kV
N2GFAF
N2GMH2G
LISH(St)CSH-TIMF SPEC
Product Download Files
Birtaş Kablo - Kumanda Kabloları 2YSLCY-J
Product Data Sheet
Local Quality Certificates
International Quality Certificates
Product Price List
Test Reports
Package Style
Summary Table
Reference Samples
EREGLI STEEL
ISKENDERUN STEEL
KARABÜK STEEL
MITTAL STEEL-ROMANYA
COLAKOGLU METALURJİ
KASTAMONU ENTEGRE
SILICONE CABLES
SIMH-FR/PF FE 180
HIGH TEMPERATURE, TWISTED PAIR RESISTANT TO FIRE SILICONE CABLES
Marking

BIRTAS KABLO SIMH FR/PF FE 180 4 x 2 x 0.50mm2 1712 05 004 TS Ex 3164 Part no GOST-R CE....mt

Applications

These twisted pairs (pair form) cables fields of use as a control and power supply cable they are fire proof and halogen free cables which, on the basis of a fixed operating mode, can continue with the supply of a power for a period of 180 minutes under the existing fire conditions (at a temperature of 750OC and under the flames ). Also these cables shall satify EN50200 test which is a fire resistant with mechancal shock test (under the conditions at 842oC and mechenical shock) by the classes PH15-PH30-PH60-PH90, if it has requsted, Because of their unique features, they can be used; on the fire alarm systems, lighting systems on the equipment and devices which are connected to the fire alarm devices, in the environments which have no corrosive gases are emitted in the event of fire. These cables are used at metro, schools, airpots, hospitals, etc.

Cable Design
ConductorIEC 60228 Class 5, TS/DIN EN 60228 Class 5
Flexible copper wires, plain;
InsulationSpeacial silicone rubber compound
Core identificationAccording to TS HD 308 S2 & VDE 0293-308
Acc. to TS/DIN EN 50334 black cores with
white numerals with green/yellow after 5 cores
Lay-upCores laid up in layers of optimum pitch
Outer sheathSilicone rubber compound
Sheath colourRAL 2009, Orange
Technical Data
StandardVDE 0250, DIN VDE 0282-15 and
TS HD 22.15 S1
(Designed according to)
Insulation resistanceMin. 20 MΩ.km
Temp. at conductor+ 180 oC
Short circuit tempetarure+200oC
Rated voltage300 / 500V
Test voltage2000 V
Temperature rangeFixed: - 60 oC ~ + 180 oC
Mobile: - 25 oC ~ + 180 oC
Min. bending radiusFixed: 4 x D
Mobile: 7,5 x D
Flame retardance testIEC 60332-1 & EN 50265-2-1
IEC 60332-3 & EN 50266-2-4
Insulation integrityIEC 60331 , VDE 0472-814
Fire resistant with mechanical shock
*Upon request
DIN EN 50200 ; PH 15 (15 minutes)
DIN EN 50200 ; PH 30 (30 minutes)
DIN EN 50200 ; PH 60 (60 minutes)
DIN EN 50200 ; PH 90 (90 minutes)
Cross Section
Part-NumberNo. of Cores x
Cross Section (mm2)
Approx. Outer Diameter (mm)Copper Weight (Kg/km)Approx. Cable Weight (Kg/km)
1712 05 0022x2x0.50 9,119105
1712 05 0044x2x0.5011,238155
1712 05 0066x2x0.5013,457175
1712 05 01010x2x0.5014,095250
1712 05 01212x2x0,5015,5115305
1712 05 01616x2x0.5018,4153400
1712 05 02020x2x0,5020,1192455
Top 