background
TR  EN  DE  RU

Products

Back to products list
Birtaş Kablo
Security, Camera & Voice Cables
CCTV
CCTV-COAX+12x0,22 mm2
CCTV-COMPOSITE
J-YY Lg
J-Y(St)Y Lg
J-Y(St)CY Lg
DT8
Product Download Files
Birtaş Kablo - Kumanda Kabloları 2YSLCY-J
Product Data Sheet
Local Quality Certificates
International Quality Certificates
Product Price List
Test Reports
Package Style
Summary Table
Reference Samples
MEDICALPARK GÖZTEPE
SHERATON ANKARA
FORMULA 1 - ISTANBUL
FORUM MERSIN SHOPPING CENTER
TEPE NAUTİLUS SHOPPING CENTER
ISTANBUL CEVAHIR SHOPPING CENTER
SECURITY, CAMERA &
VOICE CABLES
J-Y(St)CY Lg
PVC INSULATED, SCREENED FIRE ALARM INSTALLATION CABLES
Marking

BIRTAS KABLO J-Y(St)CY lg FİRE ALARM 3 x 2 x 1.38mm 1213 08 003 Part no GOST-R CE ……mt

Applications

These cables are used for fire alarm cables as an fixed indoor installations. Double screened provides more protection against electromagnetic interferences. Additionally these cables are suitable for applications at small bending radius.

Cable Design
ConductorPlain copper conductor, solid
NOTE: Upon request all conductors can be with tinned copper
InsulationPVC compound , YI1; VDE 0207-4
Core identificationVDE 0815
PairTwo conductors twisted to a pair
2 pairs twisted as star-quad
Lay-upPairs laid up in layers of optimum pitch
SeparatorPolyester tape
ScreenTinned Cu drain wire under the AL-PES tape
Drain wire;
phi : 0,40 mm ≤ 10 pairs
phi : 0,60 mm > 10 pairs
Braid of tinned Cu wires, 65% coverage
ScreenBraid of tinned Cu wires, 65% coverage
Outer sheathPVC compound, YM1; VDE 0207-5
Sheath colourRAL 7032,Grey
Technical Data
StandardVDE 0815
Conductor resistance (loop)0,60mm : 65 Ω/km
0,80mm : 36 Ω/km
1,0mm : 43,8 Ω/km
1,38mm : 23,0 Ω/km
Insulation resistanceMin. 100 MΩ.km
Mutual CapacitanceMax. 100 nF/km
This value may be exceeded by 20% by cables with up to 4 pairs
Capacitance unbalance Max. 300 pF / 100 mt
20% of the values, at least one value up to 500 pF permitted.
Test voltageCore / core & screen / core : 800 V
Temperature range- 30 oC ~ + 70 oC
Min. bending radius10xD
Flame retardance testIEC 60332-1 & EN 50265-2-1
Rated voltage, peakMax. 300 V
up to 600V permissible for short periods (6 s/min)
Cross Section
Part-NumberNo. of Cores x
Cross Section (mm2)
Approx. Outer Diameter (mm)Copper Weight (Kg/km)Approx. Cable Weight (Kg/km)
1213 03 0011x2x0,605,41745
1213 03 0022x2x0,605,62560
1213 03 0033x2x0,606,53170
1213 03 0044x2x0,607,14980
1213 03 0066x2x0,607,850100
1213 03 0088x2x0,608,362125
1213 03 01010x2x0,609,577150
1213 04 0011x2x0,806,02450
1213 04 0022x2x0,806,93770
1213 04 0033x2x0,808,648100
1213 04 0044x2x0,809,160120
1213 04 0066x2x0,8011,086160
1213 04 0088x2x0,8012,0108195
1213 04 01010x2x0,8013,2133265
1213 06 0011x2x17,13565
1213 06 0022x2x18,55290
1213 06 0033x2x110,272125
1213 06 0044x2x111,589170
1213 06 0066x2x113,7122230
1213 06 0088x2x114,9157285
1213 06 01010x2x116,5189345
1213 08 0011x2x1,388,35995
1213 08 0022x2x1,389,188145
1213 08 0033x2x1,3812,7123210
1213 08 0044x2x1,3813,9155255
1213 08 0066x2x1,3816,7220365
1213 08 0088x2x1,3818,9282465
1213 08 01010x2x1,3820,3343540
Top 