background
TR  EN  DE  RU

Products

Back to products list
Birtaş Kablo
Instrumentation Cables
500V PVC D.K. PVC -70 +150 Derece
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl MP
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl
RE-Y(St)Y-fl-PIMF &
RE-Yw(St)Yw-fl-PIMF
RE-Y(St)Y-fl-TIMF &
RE-Yw(St)Yw-fl-TIMF
RE-Y(St)YSWAY-fl &
RE-Yw(St)YwSWAYw-fl MP
RE-Y(St)YSWAY-fl &
RE-Yw(St)YwSWAYw-fl
RE-Y(St)YSWAY-fl-PIMF &
RE-Yw(St)YwSWAYw-fl-PIMF
RE-Y(St)YSWAY-fl-TIMF &
RE-Yw(St)YwSWAYw-fl-TIMF
Product Download Files
Birtaş Kablo - Kumanda Kabloları 2YSLCY-J
Product Data Sheet
Local Quality Certificates
International Quality Certificates
Product Price List
Test Reports
Package Style
Summary Table
Reference Samples
MODERN CARTON
TÜPRAS
DOLPHIN PROJECT
ISKENDERUN STEEL
COLAKOGLU METALURJİ
PASABAHCE GLASS
INSTRUMENTATION CABLES
500V PVC D.K. PVC -70 +150 DEGREE
RE-Y(St)YSWAY-fl-PIMF & RE-Yw(St)YwSWAYw-fl-PIMF
INSTRUMENTATION CABLES, EN 50288-7
MULTI-PAIR, PVC INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED
Marking

BIRTAS KABLO RE-Yw(St)YwSWAYw-fl PİMF 16 x 2 x 0.75mm2 2600 42 016 500 V EN 50288-7 -70 / +150° C Part no GOST-R CE....mt

Appliations

These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. For application of 105oC heat resistant, RE-Yw(St)YwSWAYw-PIMF cables are suitable. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits.

Cable Design
ConductorPlain copper wire, stranded
IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2
Insulation (Y)PVC compound, 70 oC grade; EN 50290-2-21
Insulation (Yw)PVC compound, 105 oC grade; EN 50290-2-21
Core identificationBlack / Blue ; with numbered tape under
separator tape of the pair screen
Upon request ; Black / Blue cores numbered 1-1, 2-2,…
Other core configurations manufactured upon request.
PairTwo conductors twisted to a pair
PIMF ConstructionPolyester tape above the pair, AL-PES tape
over solid tinned copper drain wire, 0,60 mm
Upon request ; Stranded 0,50 mm2 copper drain wire
Lay-upPIMF laid up in layers of optimum pitch
SeparatorPolyester tape
ScreenAL-PES tape over stranded tinned copper drain
wire 0,50 mm2
Inner sheath (Y)PVC compound, 70OC grade; EN 50290-2-22
Inner sheath (Yw)PVC compound, 105OC grade; EN 50290-2-22
ArmourGalvenized round steel wire, EN 10257-1
Outer sheath (Y)PVC compound, 70 oC grade; EN 50290-2-22
Outer sheath (Yw)PVC compound, 105 oC grade; EN 50290-2-22
Sheath colourRAL 9005, Black or RAL 5015, Blue
Technical Data
StandardTS/DIN EN 50288-7
Conductor resistance0,50mm2 : 36,7 Ω/km
0,75mm2 : 25,0 Ω/km
1,0mm2 : 18,5 Ω/km
1,3mm2 : 14,2 Ω/km
1,5mm2 : 12,3 Ω/km
Insulation resistanceMin. 100 MΩ.km
Mutual Capacitance0,50 mm2 : max. 160 pF/mr
0,75 mm2 : max. 160 pF/m
1,0 mm2 : max. 160 pF/m
1,3 mm2 : max. 170 pF/m
1,5 mm2 : max. 170 pF/m
L / R (ratio) (max.)0,50mm2 : 25 µH/Ω
0,75mm2 : 25 µH/Ω
1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω
1,5mm2 : 40 µH/Ω
Rated voltage500V
Test voltageUrms core-core : 2000 V
Urms core-screen : 2000 V
Temperature range (2Y)operation : - 30 oC ~ + 70 oC
ınstallation : - 5 oC ~ + 50 oC
Temperature range (2X)operation : - 30 oC ~ + 105 oC
ınstallation : - 5 oC ~ + 50 oC
Min. bending radius10 x D
Flame retardance testIEC 60332-1 & EN 60332-1
Cross Section
Part-NumberNo. of Cores x
Cross Section (mm2)
Approx. Outer Diameter (mm)Copper Weight (Kg/km)Approx. Cable Weight (Kg/km)
2600 41 002 (RE-Yw(St)YwSWAYw-fl-PIMF)2x2x0,5014,934325
1699 41 002 (RE-Y(St)YSWAY-fl-PIMF)2x2x0,5014,934340
2600 41 004 (RE-Yw(St)YwSWAYw-fl-PIMF)4x2x0,5016,762415
1699 41 004 (RE-Y(St)YSWAY-fl-PIMF)4x2x0,5016,762435
2600 41 005 (RE-Yw(St)YwSWAYw-fl-PIMF)5x2x0,5017,577455
1699 41 005 (RE-Y(St)YSWAY-fl-PIMF)5x2x0,5017,577480
2600 41 006 (RE-Yw(St)YwSWAYw-fl-PIMF)6x2x0,5018,591500
1699 41 006 (RE-Y(St)YSWAY-fl-PIMF)6x2x0,5018,591530
2600 41 008 (RE-Yw(St)YwSWAYw-fl-PIMF)8x2x0,5021,2120700
1699 41 008 (RE-Y(St)YSWAY-fl-PIMF)8x2x0,5021,2120735
2600 41 010 (RE-Yw(St)YwSWAYw-fl-PIMF)10x2x0,5022,9149805
1699 41 010 (RE-Y(St)YSWAY-fl-PIMF)10x2x0,5022,9149840
2600 41 012 (RE-Yw(St)YwSWAYw-fl-PIMF)12x2x0,5024,3178895
1699 41 012 (RE-Y(St)YSWAY-fl-PIMF)12x2x0,5024,3178930
2600 41 016 (RE-Yw(St)YwSWAYw-fl-PIMF)16x2x0,5027,02351070
1699 41 016 (RE-Y(St)YSWAY-fl-PIMF)16x2x0,5027,02351115
2600 41 020 (RE-Yw(St)YwSWAYw-fl-PIMF)20x2x0,5029,62931260
1699 41 020 (RE-Y(St)YSWAY-fl-PIMF)20x2x0,5029,62931310
2600 41 024 (RE-Yw(St)YwSWAYw-fl-PIMF)24x2x0,5032,43501590
1699 41 024 (RE-Y(St)YSWAY-fl-PIMF)24x2x0,5032,43501650
2600 42 002 (RE-Yw(St)YwSWAYw-fl-PIMF)2x2x0,7515,943360
1699 42 002 (RE-Y(St)YSWAY-fl-PIMF)2x2x0,7515,943380
2600 42 004 (RE-Yw(St)YwSWAYw-fl-PIMF)4x2x0,7517,782460
1699 42 004 (RE-Y(St)YSWAY-fl-PIMF)4x2x0,7517,782485
2600 42 005 (RE-Yw(St)YwSWAYw-fl-PIMF)5x2x0,7518,6101510
1699 42 005 (RE-Y(St)YSWAY-fl-PIMF)5x2x0,7518,6101535
2600 42 006 (RE-Yw(St)YwSWAYw-fl-PIMF)6x2x0,7520,5120675
1699 42 006 (RE-Y(St)YSWAY-fl-PIMF)6x2x0,7520,5120700
2600 42 008 (RE-Yw(St)YwSWAYw-fl-PIMF)8x2x0,7522,5158790
1699 42 008 (RE-Y(St)YSWAY-fl-PIMF)8x2x0,7522,5158825
2600 42 010 (RE-Yw(St)YwSWAYw-fl-PIMF)10x2x0,7524,4197910
1699 42 010 (RE-Y(St)YSWAY-fl-PIMF)10x2x0,7524,4197945
2600 42 012 (RE-Yw(St)YwSWAYw-fl-PIMF)12x2x0,7525,92351015
1699 42 012 (RE-Y(St)YSWAY-fl-PIMF)12x2x0,7525,92351055
2600 42 016 (RE-Yw(St)YwSWAYw-fl-PIMF)16x2x0,7528,83121225
1699 42 016 (RE-Y(St)YSWAY-fl-PIMF)16x2x0,7528,83121270
2600 42 020 (RE-Yw(St)YwSWAYw-fl-PIMF)20x2x0,7532,53891620
1699 42 020 (RE-Y(St)YSWAY-fl-PIMF)20x2x0,7532,53891680
2600 42 024 (RE-Yw(St)YwSWAYw-fl-PIMF)24x2x0,7534,94661835
1699 42 024 (RE-Y(St)YSWAY-fl-PIMF)24x2x0,7534,94661900
2600 43 002 (RE-Yw(St)YwSWAYw-fl-PIMF)2x2x116,753390
1699 43 002 (RE-Y(St)YSWAY-fl-PIMF)2x2x116,753415
2600 43 004 (RE-Yw(St)YwSWAYw-fl-PIMF)4x2x118,6101510
1699 43 004 (RE-Y(St)YSWAY-fl-PIMF)4x2x118,6101535
2600 43 005 (RE-Yw(St)YwSWAYw-fl-PIMF)5x2x120,5125675
1699 43 005 (RE-Y(St)YSWAY-fl-PIMF)5x2x120,5125705
2600 43 006 (RE-Yw(St)YwSWAYw-fl-PIMF)6x2x121,7149745
1699 43 006 (RE-Y(St)YSWAY-fl-PIMF)6x2x121,7149775
2600 43 008 (RE-Yw(St)YwSWAYw-fl-PIMF)8x2x124,0197890
1699 43 008 (RE-Y(St)YSWAY-fl-PIMF)8x2x124,0197925
2600 43 010 (RE-Yw(St)YwSWAYw-fl-PIMF)10x2x125,82451015
1699 43 010 (RE-Y(St)YSWAY-fl-PIMF)10x2x125,82451055
2600 43 012 (RE-Yw(St)YwSWAYw-fl-PIMF)12x2x127,72931150
1699 43 012 (RE-Y(St)YSWAY-fl-PIMF)12x2x127,72931195
2600 43 016 (RE-Yw(St)YwSWAYw-fl-PIMF)16x2x132,03891585
1699 43 016 (RE-Y(St)YSWAY-fl-PIMF)16x2x132,03891645
2600 43 020 (RE-Yw(St)YwSWAYw-fl-PIMF)20x2x134,84851840
1699 43 020 (RE-Y(St)YSWAY-fl-PIMF)20x2x134,84851905
2600 43 024 (RE-Yw(St)YwSWAYw-fl-PIMF)24x2x137,25812070
1699 43 024 (RE-Y(St)YSWAY-fl-PIMF)24x2x137,25812140
2600 44 002 (RE-Yw(St)YwSWAYw-fl-PIMF)2x2x1,317,664435
1699 44 002 (RE-Y(St)YSWAY-fl-PIMF)2x2x1,317,664455
2600 44 004 (RE-Yw(St)YwSWAYw-fl-PIMF)4x2x1,320,7123675
1699 44 004 (RE-Y(St)YSWAY-fl-PIMF)4x2x1,320,7123705
2600 44 005 (RE-Yw(St)YwSWAYw-fl-PIMF)5x2x1,321,8153755
1699 44 005 (RE-Y(St)YSWAY-fl-PIMF)5x2x1,321,8153785
2600 44 006 (RE-Yw(St)YwSWAYw-fl-PIMF)6x2x1,323,3183845
1699 44 006 (RE-Y(St)YSWAY-fl-PIMF)6x2x1,323,3183880
2600 44 008 (RE-Yw(St)YwSWAYw-fl-PIMF)8x2x1,325,62421000
1699 44 008 (RE-Y(St)YSWAY-fl-PIMF)8x2x1,325,62421040
2600 44 010 (RE-Yw(St)YwSWAYw-fl-PIMF)10x2x1,327,93021160
1699 44 010 (RE-Y(St)YSWAY-fl-PIMF)10x2x1,327,93021205
2600 44 012 (RE-Yw(St)YwSWAYw-fl-PIMF)12x2x1,330,13611335
1699 44 012 (RE-Y(St)YSWAY-fl-PIMF)12x2x1,330,13611385
2600 44 016 (RE-Yw(St)YwSWAYw-fl-PIMF)16x2x1,334,54801815
1699 44 016 (RE-Y(St)YSWAY-fl-PIMF)16x2x1,334,54801880
2600 44 020 (RE-Yw(St)YwSWAYw-fl-PIMF)20x2x1,337,46002095
1699 44 020 (RE-Y(St)YSWAY-fl-PIMF)20x2x1,337,46002165
2600 44 024 (RE-Yw(St)YwSWAYw-fl-PIMF)24x2x1,340,67192420
1699 44 024 (RE-Y(St)YSWAY-fl-PIMF)24x2x1,340,67192505
2600 45 002 (RE-Yw(St)YwSWAYw-fl-PIMF)2x2x1,518,272460
1699 45 002 (RE-Y(St)YSWAY-fl-PIMF)2x2x1,518,272480
2600 45 004 (RE-Yw(St)YwSWAYw-fl-PIMF)4x2x1,520,7139615
1699 45 004 (RE-Y(St)YSWAY-fl-PIMF)4x2x1,520,7139645
2600 45 005 (RE-Yw(St)YwSWAYw-fl-PIMF)5x2x1,521,9173690
1699 45 005 (RE-Y(St)YSWAY-fl-PIMF)5x2x1,521,9173725
2600 45 006 (RE-Yw(St)YwSWAYw-fl-PIMF)6x2x1,524,1206900
1699 45 006 (RE-Y(St)YSWAY-fl-PIMF)6x2x1,524,1206940
2600 45 008 (RE-Yw(St)YwSWAYw-fl-PIMF)8x2x1,526,82741085
1699 45 008 (RE-Y(St)YSWAY-fl-PIMF)8x2x1,526,82741130
2600 45 010 (RE-Yw(St)YwSWAYw-fl-PIMF)10x2x1,529,03411245
1699 45 010 (RE-Y(St)YSWAY-fl-PIMF)10x2x1,529,03411295
2600 45 012 (RE-Yw(St)YwSWAYw-fl-PIMF)12x2x1,531,54081445
1699 45 012 (RE-Y(St)YSWAY-fl-PIMF)12x2x1,531,54081500
2600 45 016 (RE-Yw(St)YwSWAYw-fl-PIMF)16x2x1,535,95421950
1699 45 016 (RE-Y(St)YSWAY-fl-PIMF)16x2x1,535,95422015
2600 45 020 (RE-Yw(St)YwSWAYw-fl-PIMF)20x2x1,539,16772270
1699 45 020 (RE-Y(St)YSWAY-fl-PIMF)20x2x1,539,16772345
2600 45 024 (RE-Yw(St)YwSWAYw-fl-PIMF)24x2x1,543,38112885
1699 45 024 (RE-Y(St)YSWAY-fl-PIMF)24x2x1,543,38112975