INSTRUMENTATION CABLES 500V PVC D.K. PE
RE-2Y(St)YSWAY-fl-PIMF & RE-2X(St)YSWAY-fl-PIMF INSTRUMENTATION CABLES, EN 50288-7 RE-2Y(St)YSWAY-fl-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED RE-2X(St)YSWAY-fl-PIMF,MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED
Marking
BIRTAS KABLO RE-2Y(St)YSWAY-fl PİMF 6 x 2 x 1.3mm2 2654 44 006 500 V EN 50288-7 90˚ C Part no GOST-R CE....mt
Applications
These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits.
Cable Design
Conductor Plain copper wire, stranded IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2
Insulation (2Y) PE compound, EN 50290-2-23; (RE-2Y….)
Insulation (2X) XLPE compound, EN 50290-2-29; (RE-2X….)
Core identification Black / Blue ; with numbered tape under separator tape of the pair screen Upon request ; Black / Blue cores numbered 1-1, 2-2,… Other core configurations manufactured upon request.
Pair Two conductors twisted to a pair
PIMF Construction Polyester tape above the pair, AL-PES tape over solid tinned copper drain wire, 0,60 mm Upon request ; Stranded 0,50 mm2 copper drain wire
Lay-up PIMF laid up in layers of optimum pitch
Screen AL-PES tape over stranded tinned copper drain wire 0,50 mm2
Inner sheath (2Y) PVC compound, EN 50290-2-22
Inner sheath (2X) PVC compound, 90 oC grade; EN 50290-2-22
Armour Galvenized round steel wire, EN 10257-1
Outer sheath (2Y) PVC comp., flame retardant; EN 50290-2-22
Outer sheath (2X) PVC compound, 90 oC grade; EN 50290-2-22
Sheath colour RAL 9005, Black or RAL 5015, Blue
Technical Data
Standard TS/DIN EN 50288-7
Conductor resistance 0,50mm2 : 36,7 Ω/km 0,75mm2 : 25,0 Ω/km 1,0mm2 : 18,5 Ω/km 1,3mm2 : 14,2 Ω/km 1,5mm2 : 12,3 Ω/km
Insulation resistance Min. 5000 MΩ.km
Mutual Capacitance max. 100 pF/m
L / R (ratio) (max.) 0,50mm2 : 25 µH/Ω 0,75mm2 : 25 µH/Ω 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω 1,5mm2 : 40 µH/Ω
Test voltage Urms core-core : 2000 V Urms core-screen : 2000 V
Temperature range (2Y) operation : - 30 oC ~ + 70 oC ınstallation : - 5 oC ~ + 50 oC
Temperature range (2X) operation : - 30 oC ~ + 90 oC ınstallation : - 5 oC ~ + 50 oC
Min. bending radius 10 x D
Alev geciktirici test IEC 60332-1 & EN 60332-1
Cross Section
Part-Number No. of Cores x Cross Section (mm2) Approx. Outer Diameter (mm) Copper Weight (Kg/km) Approx. Cable Weight (Kg/km)
2653 41 002 (RE-2Y(St)YSWAY-fl-PIMF) 2x2x0,50 14,9 34 335
2654 41 002 (RE-2X(St)YSWAY-fl-PIMF) 2x2x0,50 14,9 34 335
2654 41 004 (RE-2X(St)YSWAY-fl-PIMF) 4x2x0,50 16,7 62 425
2653 41 004 (RE-2Y(St)YSWAY-fl-PIMF) 4x2x0,50 16,7 62 425
2654 41 005 (RE-2X(St)YSWAY-fl-PIMF) 5x2x0,50 17,5 77 470
2653 41 005 (RE-2Y(St)YSWAY-fl-PIMF) 5x2x0,50 17,5 77 470
2653 41 006 (RE-2Y(St)YSWAY-fl-PIMF) 6x2x0,50 18,5 91 515
2654 41 006 (RE-2X(St)YSWAY-fl-PIMF) 6x2x0,50 18,5 91 515
2653 41 008 (RE-2Y(St)YSWAY-fl-PIMF) 8x2x0,50 21,2 120 715
2654 41 008 (RE-2X(St)YSWAY-fl-PIMF) 8x2x0,50 21,2 120 715
2653 41 010 (RE-2Y(St)YSWAY-fl-PIMF) 10x2x0,50 22,9 149 815
2654 41 010 (RE-2X(St)YSWAY-fl-PIMF) 10x2x0,50 22,9 149 815
2653 41 012 (RE-2Y(St)YSWAY-fl-PIMF) 12x2x0,50 24,3 178 905
2654 41 012 (RE-2X(St)YSWAY-fl-PIMF) 12x2x0,50 24,3 178 905
2653 41 016 (RE-2Y(St)YSWAY-fl-PIMF) 16x2x0,50 27,0 235 1080
2654 41 016 (RE-2X(St)YSWAY-fl-PIMF) 16x2x0,50 27,0 235 1080
2653 41 020 (RE-2Y(St)YSWAY-fl-PIMF) 20x2x0,50 29,6 293 1270
2654 41 020 (RE-2X(St)YSWAY-fl-PIMF) 20x2x0,50 29,6 293 1270
2653 41 024 (RE-2Y(St)YSWAY-fl-PIMF) 24x2x0,50 32,4 350 1600
2654 41 024 (RE-2X(St)YSWAY-fl-PIMF) 24x2x0,50 32,4 350 1600
2654 42 002 (RE-2X(St)YSWAY-fl-PIMF) 2x2x0,75 15,9 43 375
2653 42 002 (RE-2Y(St)YSWAY-fl-PIMF) 2x2x0,75 15,9 43 375
2654 42 004 (RE-2X(St)YSWAY-fl-PIMF) 4x2x0,75 17,7 82 475
2653 42 004 (RE-2Y(St)YSWAY-fl-PIMF) 4x2x0,75 17,7 82 475
2654 42 005 (RE-2X(St)YSWAY-fl-PIMF) 5x2x0,75 18,6 101 525
2653 42 005 (RE-2Y(St)YSWAY-fl-PIMF) 5x2x0,75 18,6 101 525
2653 42 006 (RE-2Y(St)YSWAY-fl-PIMF) 6x2x0,75 20,5 120 690
2654 42 006 (RE-2X(St)YSWAY-fl-PIMF) 6x2x0,75 20,5 120 690
2653 42 008 (RE-2Y(St)YSWAY-fl-PIMF) 8x2x0,75 22,5 158 800
2654 42 008 (RE-2X(St)YSWAY-fl-PIMF) 8x2x0,75 22,5 158 800
2653 42 010 (RE-2Y(St)YSWAY-fl-PIMF) 10x2x0,75 24,4 197 925
2654 42 010 (RE-2X(St)YSWAY-fl-PIMF) 10x2x0,75 24,4 197 925
2653 42 012 (RE-2Y(St)YSWAY-fl-PIMF) 12x2x0,75 25,9 235 1025
2654 42 012 (RE-2X(St)YSWAY-fl-PIMF) 12x2x0,75 25,9 235 1025
2653 42 016 (RE-2Y(St)YSWAY-fl-PIMF) 16x2x0,75 28,8 312 1230
2654 42 016 (RE-2X(St)YSWAY-fl-PIMF) 16x2x0,75 28,8 312 1230
2653 42 020 (RE-2Y(St)YSWAY-fl-PIMF) 20x2x0,75 32,5 389 1691
2654 42 020 (RE-2X(St)YSWAY-fl-PIMF) 20x2x0,75 32,5 389 1691
2654 42 024 (RE-2X(St)YSWAY-fl-PIMF) 24x2x0,75 34,9 466 1840
2653 42 024 (RE-2Y(St)YSWAY-fl-PIMF) 24x2x0,75 34,9 466 1840
2653 43 002 (RE-2Y(St)YSWAY-fl-PIMF) 2x2x1 16,7 53 405
2654 43 002 (RE-2X(St)YSWAY-fl-PIMF) 2x2x1 16,7 53 405
2653 43 004 (RE-2Y(St)YSWAY-fl-PIMF) 4x2x1 18,6 101 525
2654 43 004 (RE-2X(St)YSWAY-fl-PIMF) 4x2x1 18,6 101 525
2653 43 005 (RE-2Y(St)YSWAY-fl-PIMF) 5x2x1 20,5 125 685
2654 43 005 (RE-2X(St)YSWAY-fl-PIMF) 5x2x1 20,5 125 685
2653 43 006 (RE-2Y(St)YSWAY-fl-PIMF) 6x2x1 21,7 149 760
2654 43 006 (RE-2X(St)YSWAY-fl-PIMF) 6x2x1 21,7 149 760
2653 43 008 (RE-2Y(St)YSWAY-fl-PIMF) 8x2x1 24,0 197 905
2654 43 008 (RE-2X(St)YSWAY-fl-PIMF) 8x2x1 24,0 197 905
2653 43 010 (RE-2Y(St)YSWAY-fl-PIMF) 10x2x1 25,8 245 1030
2654 43 010 (RE-2X(St)YSWAY-fl-PIMF) 10x2x1 25,8 245 1030
2654 43 012 (RE-2X(St)YSWAY-fl-PIMF) 12x2x1 27,7 293 1160
2653 43 012 (RE-2Y(St)YSWAY-fl-PIMF) 12x2x1 27,7 293 1160
2653 43 016 (RE-2Y(St)YSWAY-fl-PIMF) 16x2x1 32,0 389 1600
2654 43 016 (RE-2X(St)YSWAY-fl-PIMF) 16x2x1 32,0 389 1600
2653 43 020 (RE-2Y(St)YSWAY-fl-PIMF) 20x2x1 34,8 485 1850
2654 43 020 (RE-2X(St)YSWAY-fl-PIMF) 20x2x1 34,8 485 1850
2653 43 024 (RE-2Y(St)YSWAY-fl-PIMF) 24x2x1 37,2 581 2075
2654 43 024 (RE-2X(St)YSWAY-fl-PIMF) 24x2x1 37,2 581 2075
2653 44 002 (RE-2Y(St)YSWAY-fl-PIMF) 2x2x1,3 17,6 64 445
2654 44 002 (RE-2X(St)YSWAY-fl-PIMF) 2x2x1,3 17,6 64 445
2653 44 004 (RE-2Y(St)YSWAY-fl-PIMF) 4x2x1,3 20,7 123 690
2654 44 004 (RE-2X(St)YSWAY-fl-PIMF) 4x2x1,3 20,7 123 690
2653 44 005 (RE-2Y(St)YSWAY-fl-PIMF) 5x2x1,3 21,8 153 765
2654 44 005 (RE-2X(St)YSWAY-fl-PIMF) 5x2x1,3 21,8 153 765
2653 44 006 (RE-2Y(St)YSWAY-fl-PIMF) 6x2x1,3 23,3 183 860
2654 44 006 (RE-2X(St)YSWAY-fl-PIMF) 6x2x1,3 23,3 183 860
2653 44 008 (RE-2Y(St)YSWAY-fl-PIMF) 8x2x1,3 25,6 242 1015
2654 44 008 (RE-2X(St)YSWAY-fl-PIMF) 8x2x1,3 25,6 242 1015
2654 44 010 (RE-2X(St)YSWAY-fl-PIMF) 10x2x1,3 27,9 302 1175
2653 44 010 (RE-2Y(St)YSWAY-fl-PIMF) 10x2x1,3 27,9 302 1175
2653 44 012 (RE-2Y(St)YSWAY-fl-PIMF) 12x2x1,3 30,1 361 1345
2654 44 012 (RE-2X(St)YSWAY-fl-PIMF) 12x2x1,3 30,1 361 1345
2653 44 016 (RE-2Y(St)YSWAY-fl-PIMF) 16x2x1,3 34,5 480 1825
2654 44 016 (RE-2X(St)YSWAY-fl-PIMF) 16x2x1,3 34,5 480 1825
2653 44 020 (RE-2Y(St)YSWAY-fl-PIMF) 20x2x1,3 37,4 600 2100
2654 44 020 (RE-2X(St)YSWAY-fl-PIMF) 20x2x1,3 37,4 600 2100
2653 44 024 (RE-2Y(St)YSWAY-fl-PIMF) 24x2x1,3 40,6 719 2420
2654 44 024 (RE-2X(St)YSWAY-fl-PIMF) 24x2x1,3 40,6 719 2420
2653 45 002 (RE-2Y(St)YSWAY-fl-PIMF) 2x2x1,5 18,2 72 470
2654 45 002 (RE-2X(St)YSWAY-fl-PIMF) 2x2x1,5 18,2 72 470
2653 45 004 (RE-2Y(St)YSWAY-fl-PIMF) 4x2x1,5 20,7 139 630
2654 45 004 (RE-2X(St)YSWAY-fl-PIMF) 4x2x1,5 20,7 139 630
2653 45 005 (RE-2Y(St)YSWAY-fl-PIMF) 5x2x1,5 21,9 173 705
2654 45 005 (RE-2X(St)YSWAY-fl-PIMF) 5x2x1,5 21,9 173 705
2653 45 006 (RE-2Y(St)YSWAY-fl-PIMF) 6x2x1,5 24,1 206 915
2654 45 006 (RE-2X(St)YSWAY-fl-PIMF) 6x2x1,5 24,1 206 915
2653 45 008 (RE-2Y(St)YSWAY-fl-PIMF) 8x2x1,5 26,8 274 1100
2654 45 008 (RE-2X(St)YSWAY-fl-PIMF) 8x2x1,5 26,8 274 1100
2653 45 010 (RE-2Y(St)YSWAY-fl-PIMF) 10x2x1,5 29,0 341 1260
2654 45 010 (RE-2X(St)YSWAY-fl-PIMF) 10x2x1,5 29,0 341 1260
2653 45 012 (RE-2Y(St)YSWAY-fl-PIMF) 12x2x1,5 31,5 408 1460
2654 45 012 (RE-2X(St)YSWAY-fl-PIMF) 12x2x1,5 31,5 408 1460
2654 45 016 (RE-2X(St)YSWAY-fl-PIMF) 16x2x1,5 35,9 542 1960
2653 45 016 (RE-2Y(St)YSWAY-fl-PIMF) 16x2x1,5 35,9 542 1960
2653 45 020 (RE-2Y(St)YSWAY-fl-PIMF) 20x2x1,5 39,1 677 2275
2654 45 020 (RE-2X(St)YSWAY-fl-PIMF) 20x2x1,5 39,1 677 2275
2654 45 024 (RE-2X(St)YSWAY-fl-PIMF) 24x2x1,5 43,3 811 2890
2653 45 024 (RE-2Y(St)YSWAY-fl-PIMF) 24x2x1,5 43,3 811 2890