300V PVC D.K. PVC -70 +150 Derece
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl MP
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl
RE-Y(St)Y-fl-PIMF &
RE-Yw(St)Yw-fl-PIMF
RE-Y(St)Y-fl-TIMF &
RE-Yw(St)Yw-fl-TIM
RE-Y(St)YSWAY-fl &
RE-Yw(St)YwSWAYw-fl MP
RE-Y(St)YSWAY-fl &
RE-Yw(St)YwSWAYw-fl
RE-Y(St)YSWAY-fl-PIMF &
RE-Yw(St)YwSWAYw-fl-PIMF
RE-Y(St)YSWAY-fl-TIMF &
RE-Yw(St)YwSWAYw-fl-TIMF
Product Download Files
Birtaş Kablo - Kumanda Kabloları 2YSLCY-J
Product Data Sheet
Local Quality Certificates
International Quality Certificates
Product Price List
Test Reports
Package Style
Summary Table
Reference Samples
MODERN CARTON
TÜPRAS
DOLPHIN PROJECT
ISKENDERUN STEEL
COLAKOGLU METALURJİ
PASABAHCE GLASS
INSTRUMENTATION CABLES
300V PVC D.K. PVC -70 +150 DEGREE
RE-Y(St)YSWAY-fl & RE-Yw(St)YwSWAYw-fl MP
INSTRUMENTATION CABLES, EN 50288-7
SINGLE & MULTI-PAIR, PVC INSULATED, COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED
Marking

BIRTAS KABLO RE-Yw(St)YwSWAYw-fl MP 4 x 2 x 1mm2 1639 43 004 EN 50288-7 -70 / +150˚ C Part no GOST-R CE....mt

Applications

These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. For application of 105oC heat resistant, RE-Yw(St)YwSWAYw cables are suitable. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits.

Cable Design
ConductorPlain copper wire, stranded
IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2
Insulation (Y)PVC compound, 70 oC grade; EN 50290-2-21
Insulation (Yw)PVC compound, 105 oC grade; EN 50290-2-21
Core identificationBlack / White cores numbered 1-1, 2-2,…
Upon request ; Colour coded according to IEC 60189-2
Other core configurations manufactured upon request.
PairTwo conductors twisted to a pair
Lay-upPairs laid up in layers of optimum pitch
SeparatorPolyester tape
ScreenAL-PES tape over stranded tinned copper drain
wire 0,50 mm2
Inner sheath (Y)PVC compound, 70 oC grade; EN 50290-2-22
Inner sheath (Yw)PVC compound, 105 oC grade; EN 50290-2-22
ArmourGalvenized round steel wire, EN 10257-1
Outer sheath (Y)PVC compound, 70oC grade; EN 50290-2-22
Outer sheath (Yw)PVC compound, 105 oC grade; EN 50290-2-22
Sheath colourRAL 9005, Black or RAL 5015, Blue
Technical Data
StandardTS/DIN EN 50288-7
Insulation thickness0,50mm2 : 0,40 mm
0,75mm2 : 0,40 mm
1,0mm2 : 0,40 mm
1,3mm2 : 0,45 mm
1,5mm2 : 0,45 mm
Conductor resistance0,50mm2 : 36,7 Ω/km
0,75mm2 : 25,0 Ω/km
1,0mm2 : 18,5 Ω/km
1,3mm2 : 14,2 Ω/km
1,5mm2 : 12,3 Ω/km
Insulation resistanceMin. 100 MΩ.km
Mutual Capacitance0,50 mm2 : max. 190 pF/m ≤ 4 pairs,max. 150 pF/m all other pairs
0,75 mm2 : max. 190 pF/m ≤ 4 pairs,max. 150 pF/m all other pairs
1,0 mm2 : max. 190 pF/m ≤ 4 pairs,max. 150 pF/m all other pairs
1,3 mm2 : max. 200 pF/m ≤ 4 pairs,max. 160 pF/m all other pairs
1,5 mm2 : max. 200 pF/m ≤ 4 pairs,max. 160 pF/m all other pairs
Capacitance unbalance (1 kHz) : max. 500 pF/500 m
L / R (ratio) (max.)0,50mm2 : 25 µH/Ω
0,75mm2 : 25 µH/Ω
1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω
1,5mm2 : 40 µH/Ω
Rated voltage300V
Test voltageUrms core-core : 1500 V
Urms core-screen : 1500 V
Temperature range (2Y)operation : - 30 oC ~ + 70 oC
ınstallation : - 5 oC ~ + 50 oC
Temperature range (2X)operation : - 30 oC ~ + 105 oC
ınstallation : - 5 oC ~ + 50 oC
Min. bending radius10 x D
Flame retardance test IEC 60332-1 & EN 60332-1
Cross Section
Part-NumberNo. of Cores x
Cross Section (mm2)
Approx. Outer Diameter (mm)Copper Weight (Kg/km)Approx. Cable Weight (Kg/km)
1639 41 001 (RE-Y(St)YSWAY-fl)1x2x0,5010,214190
1639 41 002 (RE-Y(St)YSWAY-fl)2x2x0,5012,724275
1639 41 004 (RE-Y(St)YSWAY-fl)4x2x0,5014,043335
1639 41 005 (RE-Y(St)YSWAY-fl)5x2x0,5014,553360
1639 41 006 (RE-Y(St)YSWAY-fl)6x2x0,5015,462400
1639 41 008 (RE-Y(St)YSWAY-fl)8x2x0,5016,682465
1639 41 010 (RE-Y(St)YSWAY-fl)10x2x0,5017,7101525
1639 41 012 (RE-Y(St)YSWAY-fl)12x2x0,5018,7120580
1639 41 016 (RE-Y(St)YSWAY-fl)16x2x0,5021,4158800
1639 41 020 (RE-Y(St)YSWAY-fl)20x2x0,5023,2197920
1639 41 024 (RE-Y(St)YSWAY-fl)24x2x0,5024,62351025
1639 42 001 (RE-Y(St)YSWAY-fl)1x2x0,7510,619205
1639 42 002 (RE-Y(St)YSWAY-fl)2x2x0,7513,434300
1639 42 004 (RE-Y(St)YSWAY-fl)4x2x0,7514,862380
1639 42 005 (RE-Y(St)YSWAY-fl)5x2x0,7515,577420
1639 42 006 (RE-Y(St)YSWAY-fl)6x2x0,7516,391460
1639 42 008 (RE-Y(St)YSWAY-fl)8x2x0,7517,7120540
1639 42 010 (RE-Y(St)YSWAY-fl)10x2x0,7519,0149610
1639 42 012 (RE-Y(St)YSWAY-fl)12x2x0,7521,0178795
1639 42 016 (RE-Y(St)YSWAY-fl)16x2x0,7523,2235950
1639 42 020 (RE-Y(St)YSWAY-fl)20x2x0,7525,02931090
1639 42 024 (RE-Y(St)YSWAY-fl)24x2x0,7526,73501235
1639 43 001 (RE-Y(St)YSWAY-fl)1x2x111,024220
1639 43 002 (RE-Y(St)YSWAY-fl)2x2x114,143330
1639 43 004 (RE-Y(St)YSWAY-fl)4x2x115,982430
1639 43 005 (RE-Y(St)YSWAY-fl)5x2x116,4101470
1639 43 006 (RE-Y(St)YSWAY-fl)6x2x117,3120520
1639 43 008 (RE-Y(St)YSWAY-fl)8x2x118,8158615
1639 43 010 (RE-Y(St)YSWAY-fl)10x2x121,1197815
1639 43 012 (RE-Y(St)YSWAY-fl)12x2x122,4235905
1639 43 016 (RE-Y(St)YSWAY-fl)16x2x124,83121095
1639 43 020 (RE-Y(St)YSWAY-fl)20x2x126,93891275
1639 43 024 (RE-Y(St)YSWAY-fl)24x2x128,74661440
1639 44 001 (RE-Y(St)YSWAY-fl)1x2x1,311,830250
1639 44 002 (RE-Y(St)YSWAY-fl)2x2x1,315,155370
1639 44 004 (RE-Y(St)YSWAY-fl)4x2x1,317,1105495
1639 44 005 (RE-Y(St)YSWAY-fl)5x2x1,317,7130545
1639 44 006 (RE-Y(St)YSWAY-fl)6x2x1,318,7155605
1639 44 008 (RE-Y(St)YSWAY-fl)8x2x1,321,4204835
1639 44 010 (RE-Y(St)YSWAY-fl)10x2x1,323,0254955
1639 44 012 (RE-Y(St)YSWAY-fl)12x2x1,324,63041080
1639 44 016 (RE-Y(St)YSWAY-fl)16x2x1,327,34041310
1639 44 020 (RE-Y(St)YSWAY-fl)20x2x1,329,55041520
1639 44 024 (RE-Y(St)YSWAY-fl)24x2x1,332,86041945
1639 45 001 (RE-Y(St)YSWAY-fl)1x2x1,512,034260
1639 45 002 (RE-Y(St)YSWAY-fl)2x2x1,515,662395
1639 45 004 (RE-Y(St)YSWAY-fl)4x2x1,517,5120520
1639 45 005 (RE-Y(St)YSWAY-fl)5x2x1,518,2149575
1639 45 006 (RE-Y(St)YSWAY-fl)6x2x1,520,1178750
1639 45 008 (RE-Y(St)YSWAY-fl)8x2x1,522,0235885
1639 45 010 (RE-Y(St)YSWAY-fl)10x2x1,523,82931025
1639 45 012 (RE-Y(St)YSWAY-fl)12x2x1,525,33501155
1639 45 016 (RE-Y(St)YSWAY-fl)16x2x1,528,14661405
1639 45 020 (RE-Y(St)YSWAY-fl)20x2x1,530,65811650
1639 45 024 (RE-Y(St)YSWAY-fl)24x2x1,533,86962085