Birtaş Kablo
Product Download Files
Birtaş Kablo - Kumanda Kabloları 2YSLCY-J
Product Data Sheet
Local Quality Certificates
International Quality Certificates
Product Price List
Test Reports
Package Style
Summary Table
Reference Samples
MODERN CARTON
TÜPRAS
DOLPHIN PROJECT
ISKENDERUN STEEL
COLAKOGLU METALURJİ
PASABAHCE GLASS
INSTRUMENTATION CABLES 300V HFFR
RE-2Y(St)HSWAH-PIMF & RE-2X(St)HSWAH-PIMF HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7 RE-2Y(St)HSWAH-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED RE-2X(St)HSWAH-PIMF,MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED
Marking
BIRTAS KABLO RE-2Y(St)HSWAH PİMF 10 x 2 x 0.50mm2 1683 41 010 300 V EN 50288-7 Part no GOST-R CE....mt
Applications
These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits.
Cable Design
Conductor Plain copper wire, stranded IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2
Insulation (2Y) PE compound, EN 50290-2-23; (RE-2Y….)
Insulation (2X) XLPE compound, EN 50290-2-29; (RE-2X….)
Core identification Black / White ; with numbered tape under separator tape of the pair screen Upon request ; Black / White cores numbered 1-1, 2-2,… Other core configurations manufactured upon request.
Pair Two conductors twisted to a pair
PIMF Construction Polyester tape above the pair, AL-PES tape over solid tinned copper drain wire, 0,60 mm Upon request ; Stranded 0,50 mm2 copper drain wire
Lay-up PIMF laid up in layers of optimum pitch
Screen AL-PES tape over stranded tinned copper drain wire 0,50 mm2
Inner sheath HFFR compound, EN 50290-2-27
Armour Galvenized round steel wire, EN 10257-1
Outer sheath HFFR compound, EN 50290-2-27
Sheath colour RAL 9005, Black or RAL 5015, Blue
Technical Data
Standard TS/DIN EN 50288-7
Insulation thickness 0,50mm2 : 0,40 mm 0,75mm2 : 0,40 mm 1,0mm2 : 0,40 mm 1,3mm2 : 0,45 mm 1,5mm2 : 0,45 mm
Conductor resistance 0,50mm2 : 36,7 Ω/km 0,75mm2 : 25,0 Ω/km 1,0mm2 : 18,5 Ω/km 1,3mm2 : 14,2 Ω/km 1,5mm2 : 12,3 Ω/km
Insulation resistance Min. 5000 MΩ.km
Mutual Capacitance max. 120 pF/m
L / R (ratio) (max.) 0,50mm2 : 25 µH/Ω 0,75mm2 : 25 µH/Ω 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω 1,5mm2 : 40 µH/Ω
Test voltage Urms core-core : 1500 V Urms core-screen : 1500 V
Temperature range (2Y) operation : - 30 oC ~ + 70 oC ınstallation : - 5 oC ~ + 50 oC
Temperature range (2X) operation : - 30 oC ~ + 90 oC ınstallation : - 5 oC ~ + 50 oC
Min. bending radius 10 x D
Flame test IEC 60332-1 & TS/DIN EN 60332-1 IEC 60332-3 & TS/DIN EN 50266-2-4
Smoke density test IEC 61034-2 & TS/DIN EN 61034-2
Halogen-free properties test IEC60754-1/2 & TS/DIN EN 50267-2
Cross Section
Part-Number No. of Cores x Cross Section (mm2) Approx. Outer Diameter (mm) Copper Weight (Kg/km) Approx. Cable Weight (Kg/km)
1683 41 002 (RE-2Y(St)HSWAH-PIMF) 2x2x0,50 13,7 34 315
1684 41 002 (RE-2X(St)HSWAH-PIMF) 2x2x0,50 13,7 34 315
1684 41 004 (RE-2X(St)HSWAH-PIMF) 4x2x0,50 15,1 62 385
1683 41 004 (RE-2Y(St)HSWAH-PIMF) 4x2x0,50 15,1 62 385
1684 41 005 (RE-2X(St)HSWAH-PIMF) 5x2x0,50 16,0 77 430
1683 41 005 (RE-2Y(St)HSWAH-PIMF) 5x2x0,50 16,0 77 430
1683 41 006 (RE-2Y(St)HSWAH-PIMF) 6x2x0,50 16,8 91 475
1684 41 006 (RE-2X(St)HSWAH-PIMF) 6x2x0,50 16,8 91 475
1683 41 008 (RE-2Y(St)HSWAH-PIMF) 8x2x0,50 18,3 120 550
1684 41 008 (RE-2X(St)HSWAH-PIMF) 8x2x0,50 18,3 120 550
1683 41 010 (RE-2Y(St)HSWAH-PIMF) 10x2x0,50 19,8 149 635
1684 41 010 (RE-2X(St)HSWAH-PIMF) 10x2x0,50 19,8 149 635
1683 41 012 (RE-2Y(St)HSWAH-PIMF) 12x2x0,50 21,7 178 810
1684 41 012 (RE-2X(St)HSWAH-PIMF) 12x2x0,50 21,7 178 810
1683 41 016 (RE-2Y(St)HSWAH-PIMF) 16x2x0,50 24,0 235 965
1684 41 016 (RE-2X(St)HSWAH-PIMF) 16x2x0,50 24,0 235 965
1683 41 020 (RE-2Y(St)HSWAH-PIMF) 20x2x0,50 25,9 293 1105
1684 41 020 (RE-2X(St)HSWAH-PIMF) 20x2x0,50 25,9 293 1105
1683 41 024 (RE-2Y(St)HSWAH-PIMF) 24x2x0,50 27,7 350 1250
1684 41 024 (RE-2X(St)HSWAH-PIMF) 24x2x0,50 27,7 350 1250
1684 42 002 (RE-2X(St)HSWAH-PIMF) 2x2x0,75 14,5 43 345
1683 42 002 (RE-2Y(St)HSWAH-PIMF) 2x2x0,75 14,5 43 345
1684 42 004 (RE-2X(St)HSWAH-PIMF) 4x2x0,75 16,2 82 445
1683 42 004 (RE-2Y(St)HSWAH-PIMF) 4x2x0,75 16,2 82 445
1684 42 005 (RE-2X(St)HSWAH-PIMF) 5x2x0,75 17,0 101 490
1683 42 005 (RE-2Y(St)HSWAH-PIMF) 5x2x0,75 17,0 101 490
1683 42 006 (RE-2Y(St)HSWAH-PIMF) 6x2x0,75 18,0 120 540
1684 42 006 (RE-2X(St)HSWAH-PIMF) 6x2x0,75 18,0 120 540
1683 42 008 (RE-2Y(St)HSWAH-PIMF) 8x2x0,75 20,5 158 740
1684 42 008 (RE-2X(St)HSWAH-PIMF) 8x2x0,75 20,5 158 740
1683 42 010 (RE-2Y(St)HSWAH-PIMF) 10x2x0,75 22,0 197 835
1684 42 010 (RE-2X(St)HSWAH-PIMF) 10x2x0,75 22,0 197 835
1683 42 012 (RE-2Y(St)HSWAH-PIMF) 12x2x0,75 23,5 235 940
1684 42 012 (RE-2X(St)HSWAH-PIMF) 12x2x0,75 23,5 235 940
1683 42 016 (RE-2Y(St)HSWAH-PIMF) 16x2x0,75 25,9 312 1115
1684 42 016 (RE-2X(St)HSWAH-PIMF) 16x2x0,75 25,9 312 1115
1683 42 020 (RE-2Y(St)HSWAH-PIMF) 20x2x0,75 28,1 389 1295
1684 42 020 (RE-2X(St)HSWAH-PIMF) 20x2x0,75 28,1 389 1295
1684 42 024 (RE-2X(St)HSWAH-PIMF) 24x2x0,75 30,6 466 1505
1683 42 024 (RE-2Y(St)HSWAH-PIMF) 24x2x0,75 30,6 466 1505
1683 43 002 (RE-2Y(St)HSWAH-PIMF) 2x2x1 15,3 53 380
1684 43 002 (RE-2X(St)HSWAH-PIMF) 2x2x1 15,3 53 380
1683 43 004 (RE-2Y(St)HSWAH-PIMF) 4x2x1 17,2 101 490
1684 43 004 (RE-2X(St)HSWAH-PIMF) 4x2x1 17,2 101 490
1683 43 005 (RE-2Y(St)HSWAH-PIMF) 5x2x1 18,0 125 545
1684 43 005 (RE-2X(St)HSWAH-PIMF) 5x2x1 18,0 125 545
1683 43 006 (RE-2Y(St)HSWAH-PIMF) 6x2x1 20,0 149 705
1684 43 006 (RE-2X(St)HSWAH-PIMF) 6x2x1 20,0 149 705
1683 43 008 (RE-2Y(St)HSWAH-PIMF) 8x2x1 21,8 197 825
1684 43 008 (RE-2X(St)HSWAH-PIMF) 8x2x1 21,8 197 825
1683 43 010 (RE-2Y(St)HSWAH-PIMF) 10x2x1 23,6 245 955
1684 43 010 (RE-2X(St)HSWAH-PIMF) 10x2x1 23,6 245 955
1684 43 012 (RE-2X(St)HSWAH-PIMF) 12x2x1 25,1 293 1060
1683 43 012 (RE-2Y(St)HSWAH-PIMF) 12x2x1 25,1 293 1060
1683 43 016 (RE-2Y(St)HSWAH-PIMF) 16x2x1 27,9 389 1280
1684 43 016 (RE-2X(St)HSWAH-PIMF) 16x2x1 27,9 389 1280
1683 43 020 (RE-2Y(St)HSWAH-PIMF) 20x2x1 31,5 485 1690
1684 43 020 (RE-2X(St)HSWAH-PIMF) 20x2x1 31,5 485 1690
1683 43 024 (RE-2Y(St)HSWAH-PIMF) 24x2x1 33,6 581 1895
1684 43 024 (RE-2X(St)HSWAH-PIMF) 24x2x1 33,6 581 1895
1683 44 002 (RE-2Y(St)HSWAH-PIMF) 2x2x1,3 16,7 64 430
1684 44 002 (RE-2X(St)HSWAH-PIMF) 2x2x1,3 16,7 64 430
1683 44 004 (RE-2Y(St)HSWAH-PIMF) 4x2x1,3 18,6 123 560
1684 44 004 (RE-2X(St)HSWAH-PIMF) 4x2x1,3 18,6 123 560
1683 44 005 (RE-2Y(St)HSWAH-PIMF) 5x2x1,3 20,5 153 735
1684 44 005 (RE-2X(St)HSWAH-PIMF) 5x2x1,3 20,5 153 735
1683 44 006 (RE-2Y(St)HSWAH-PIMF) 6x2x1,3 21,7 183 810
1684 44 006 (RE-2X(St)HSWAH-PIMF) 6x2x1,3 21,7 183 810
1683 44 008 (RE-2Y(St)HSWAH-PIMF) 8x2x1,3 24,0 242 965
1684 44 008 (RE-2X(St)HSWAH-PIMF) 8x2x1,3 24,0 242 965
1684 44 010 (RE-2X(St)HSWAH-PIMF) 10x2x1,3 25,8 302 1105
1683 44 010 (RE-2Y(St)HSWAH-PIMF) 10x2x1,3 25,8 302 1105
1683 44 012 (RE-2Y(St)HSWAH-PIMF) 12x2x1,3 27,7 361 1250
1684 44 012 (RE-2X(St)HSWAH-PIMF) 12x2x1,3 27,7 361 1250
1683 44 016 (RE-2Y(St)HSWAH-PIMF) 16x2x1,3 31,6 480 1676
1684 44 016 (RE-2X(St)HSWAH-PIMF) 16x2x1,3 31,6 480 1676
1683 44 020 (RE-2Y(St)HSWAH-PIMF) 20x2x1,3 34,8 600 1990
1684 44 020 (RE-2X(St)HSWAH-PIMF) 20x2x1,3 34,8 600 1990
1683 44 024 (RE-2Y(St)HSWAH-PIMF) 24x2x1,3 37,2 719 2235
1684 44 024 (RE-2X(St)HSWAH-PIMF) 24x2x1,3 37,2 719 2235
1683 45 002 (RE-2Y(St)HSWAH-PIMF) 2x2x1,5 17,0 72 455
1684 45 002 (RE-2X(St)HSWAH-PIMF) 2x2x1,5 17,0 72 455
1683 45 004 (RE-2Y(St)HSWAH-PIMF) 4x2x1,5 19,1 139 590
1684 45 004 (RE-2X(St)HSWAH-PIMF) 4x2x1,5 19,1 139 590
1683 45 005 (RE-2Y(St)HSWAH-PIMF) 5x2x1,5 20,3 173 665
1684 45 005 (RE-2X(St)HSWAH-PIMF) 5x2x1,5 20,3 173 665
1683 45 006 (RE-2Y(St)HSWAH-PIMF) 6x2x1,5 22,2 206 850
1684 45 006 (RE-2X(St)HSWAH-PIMF) 6x2x1,5 22,2 206 850
1683 45 008 (RE-2Y(St)HSWAH-PIMF) 8x2x1,5 24,6 274 1020
1684 45 008 (RE-2X(St)HSWAH-PIMF) 8x2x1,5 24,6 274 1020
1683 45 010 (RE-2Y(St)HSWAH-PIMF) 10x2x1,5 26,8 341 1180
1684 45 010 (RE-2X(St)HSWAH-PIMF) 10x2x1,5 26,8 341 1180
1683 45 012 (RE-2Y(St)HSWAH-PIMF) 12x2x1,5 28,5 408 1325
1684 45 012 (RE-2X(St)HSWAH-PIMF) 12x2x1,5 28,5 408 1325
1684 45 016 (RE-2X(St)HSWAH-PIMF) 16x2x1,5 32,9 542 1820
1683 45 016 (RE-2Y(St)HSWAH-PIMF) 16x2x1,5 32,9 542 1820
1683 45 020 (RE-2Y(St)HSWAH-PIMF) 20x2x1,5 35,8 677 2115
1684 45 020 (RE-2X(St)HSWAH-PIMF) 20x2x1,5 35,8 677 2115
1684 45 024 (RE-2X(St)HSWAH-PIMF) 24x2x1,5 38,5 811 2400
1683 45 024 (RE-2Y(St)HSWAH-PIMF) 24x2x1,5 38,5 811 2400