Halogen Free Installation & Energy Cables
H05Z-U & H07Z-U/R & H05Z/K & H07Z/K
H05Z1-U & H07Z1-U/R & H05Z1/K & H07Z1/K
H03Z1Z1-F 300/300 V & H05Z1Z1-F 300/500 V
NHMH
NHXMH
N2XH
N2XCH
NHXMH FE180
N2XH FE180
(N)2GH FE180
(N)2GH FE180 - FLEX
(N)HXH FE180 E30
(N)HXH FE180 E90
(N)HXCH FE180 – E30
(N)HXCH FE180 – E90
Cu/XLPE/LSZH/SWA/LSZH – MULTICORE – BS 6724
2XHRH
Product Download Files
Birtaş Kablo - Kumanda Kabloları 2YSLCY-J
Product Data Sheet
Local Quality Certificates
International Quality Certificates
Product Price List
Test Reports
Package Style
Summary Table
Reference Samples
ISTINYE PARK SHOPPING CENTER
KORUPARK SHOPPING CENTER
FORUM MERSİN SHOPPING CENTER
CEPA SHOPPING CENTER
KANYON SHOPPING CENTER
ISTANBUL TEKSTİLKENT
HALOGEN FREE INSTALLATION & ENERGY CABLES
N2XH FE180
HALOGEN-FREE, ENERGY SAFETY CABLES, 0,6/1 kV
Marking

BIRTAS KABLO N2XH FE 180 2 x 10 (re) mm2 1991 19 002 Part no GOST-R CE … mt

Applications

These halogen-free cables fields of use are fire proof and halogen free cables which, on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions. These halogen-free safety cables are used as energy, utility and lighting cables in dry, moist and wet rooms, for permanent installation above, on, in and under beneath plaster and also for outdoor applications where lots of human life and material assets are to be protected in industrial constructions, schools, hospitals, shopping and cultural centers,energy plants, airports, metros . In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire.

Cable Design
ConductorCu wires,plain, solid-core, multi-stranded
IEC 60228 Cls. 1/2, TS/DIN EN 60228 Cls. 1/2
InsulationDouble layer ,mica tape and XLPE polymer
Core identificationAccording to TS HD 308 S2 & VDE 0293-308;
Note: Other core configurations manufactured upon request.
Lay-upCores laid up in layers of optimum pitch
FillerHFFR filler compound
Outer sheathHFFR compound, HM4, VDE 0276-604
HFFR: Halogen-free flame retardant
Sheath colourRAL 2003, Orange or RAL 9005, Black
Technical Data
StandardDIN VDE 0276-604 & TS HD 604 S1
(Designed according to)
Temp. at conductor90 oC
Rated voltage0,6 / 1 kV
Test voltage4000 V
Temperature rangeFixed: - 30 oC ~ + 90 oC
Mobile: - 5 oC ~ + 50 oC
Min. bending radiusSıngle-core: 15 x D
Multi-core: 12 x D
Smoke density testIEC 61034-2 & TS/DIN EN 61034-2
Halogen-free properties testIEC60754-1/2 & TS/DIN EN 50267-2
Flame testIEC 60332-3 & TS/DIN EN 50266-2-4
Insulation integrityIEC 60331 , VDE 0472-814
Cross Section
Part-NumberNo. of Cores x
Cross Section (mm2)
Approx. Outer Diameter (mm)Copper Weight (Kg/km)Approx. Cable Weight (Kg/km)
1991 15 0022x1,5 re9,829125
1991 15 0033x1,5 re10,543145
1991 15 0044x1,5 re11,058175
1991 15 0055x1,5 re12,072215
1991 15 0077x1,5 re12,9101250
1991 15 01010x1,5 re16,1144360
1991 16 0022x2,5 re10,548160
1991 16 0033x2,5 re11,172190
1991 16 0044x2,5 re12,196225
1991 16 0055x2,5 re13,2120275
1991 16 0077x2,5 re14,3168330
1991 16 01010x2,5 re18,3240475
1991 17 0011x4 re6,83980
1991 18 0011x6 re7,558115
1991 19 0011x10 re8,596175
1991 20 0011x16 re9,9154245
1991 18 0022x6 re12,2115260
1991 18 0033x6 re13,2173320
1991 51 0011x25 rm10,4240345
1991 19 0022x10 re15,2192405
1991 18 0044x6 re14,8230415
1991 18 0055x6 re16,0288460
1991 52 0011x35 rm11,9336460
1991 19 0033x10 re16,0288500
1991 19 0044x10 re17,2384625
1991 50 0022x16 rm18,4307710
1991 19 0055x10 re18,9480740
1991 50 0033x16 rm20,1460850
1991 50 0044x16 rm22,5614950
1991 51 0022x25 rm22,4480980
1991 50 0055x16 rm23,97681020
1991 52 0022x35 rm25,16721150
1991 51 0033x25 rm24,17201210
1991 51 0044x25 rm26,99601480
1991 52 0033x35 rm27,110081520
1991 51 0055x25 rm29,112001820
1991 52 0044x35 rm29,813441950
1991 52 0055x35 rm33,116802320