background
TR  EN  DE  RU

Products

Back to products list
Birtaş Kablo
Control Cables
BIRTFLEX 552 / YSLY
BIRTFLEX 552-CY / YSLYCY
BIRTFLEX 552-SY / YSLYSY
BIRTFLEX 572
BIRTFLEX 572 CY-JB
BIRTFLEX 572 SY-JB
BIRTFLEX 532 / NLSY
BIRTFLEX 532-CY / NLSCY
BIRTFLEX 555 / HO5VV5-F
(NYSLYÖ-JZ/OZ)
BIRTFLEX 555-CY / HO5VVC4V5-K (NYSLYCYÖ-JZ/OZ)
BIRTFLEX 556 / H05V2V2-F
BIRTFLEX 556-CY (H05V2V2C4V2-K)
BIRTFLEX-EF 655
BIRTFLEX-EF 655-CY
BIRTFLEX-EF 656
BIRTFLEX-EF 656-CY
BIRTFLEX 5511-PUR
BIRTFLEX 5511-C-PUR
BIRTFLEX-EF 6511-PUR
BIRTFLEX-EF 6511-C-PUR
BIRTFLEX-EF 6512-PUR
BIRTFLEX-EF 6512-C-PUR
BIRTFLEX 515
BIRTFLEX 515 CY
BIRTFLEX 515 S/C &
BIRTFLEX 616 S/C
2YSLCY-J
HO5VVH6-F (300/500 V) &
H07VVH6-F (450/750 V)
BIRTFLEX-EF 659-PUR
BIRTFLEX-EF 659-C-PUR
BIRTFLEX 552-C / YSLCY
Product Download Files
Birtaş Kablo - Kumanda Kabloları 2YSLCY-J
Product Data Sheet
Local Quality Certificates
International Quality Certificates
Product Price List
Test Reports
Package Style
Summary Table
Reference Samples
MODERN CARTON
EREGLİ STEEL
ISKENDERUN STEEL
KARABÜK STEEL
MITTAL STEEL-ROMANYA
KASTAMONU ENTEGRE
DURMAZLAR MAKINA
TRAKYA GLSS
CONTROL CABLES
BIRTFLEX 556-CY (H05V2V2C4V2-K)
PVC INSULATED, SCREENED HIGH TEMPERATURE, OIL RESISTANT CONTROL CABLES
Marking

BIRTAS KABLO BIRTFLEX 556-CY/H05V2V2C4V2-K 3 G 2.5mm2 1012 09 003 TS HD 21.12 S1 Part no GOST-R CE mt.

Application

These high temperature 90oC grade, flexible cables are used in mechanical engineering for instrumentation and control equipment for tooling machinery production lines and flexible applications for free movement without tensile load and witout forced movement, in dry, moist and wet rooms. The screen above the inner sheat protects against external interference pulses and ensures an interference-free transmission, and transfer impedance is max. 250 ?/km at 30MHZ. These cables are not used for outdoor or underground installation.

Cable Design
ConductorFlexible copper wires, plain; IEC 60228 Class 5, TS/DIN EN 60228 Class 5
InsulationPVC compound ,90o grade, TI3
Core identificationAcc. to TS/DIN EN 50334 black cores with white numerals with green/yellow from 3 cores
Lay-upCores laid up in layers of optimum pitch
Inner SheathPVC compound, 90o grade, TI3TM3;Grey
ScreenBraid of tinned copper wires, 85% coverage
Outer sheathOil and flame resistant PVC compound, 90oC
Sheath colourRAL 7001, Grey
Technical Data
StandardTS HD 21.13 S1, DIN VDE 0281-13TS HD 21.12 S1, DIN VDE 0281-12
Insulation resistanceMin. 50 MΩ.km
Rated voltage Uo/U300 / 500V
Test voltage4000 V
Temperature rangeFixed: - 40 oC ~ + 90 oC; Mobile: - 5 oC ~ + 90 oC
Min. bending radiusFixed: 6 x D; Mobile: 12,5 x D
Flame retardance testIEC 60332-1 & EN 50265-2-1
Oil testIEC 60811-2-1
Transfer impedanceMax. 250 MΩ/km at 30MHZ
EMCELECTROMAGNETIC COMPATIBILITY
Cross Section
Part-NumberNo. of Cores x
Cross Section (mm2)
Approx. Outer Diameter (mm)Copper Weight (Kg/km)Approx. Cable Weight (Kg/km)
1012 06 0033G0,758,750110
1012 06 004 4G0,759,960145
1012 06 0055G0,7510,675170
1012 06 0077G0,7511,894215
1012 06 01212G0,7514,8155305
1012 06 01818G0,7517,8210455
1012 06 02424G0,7520,6270590
1012 06 03030G0,7522,1325715
1012 06 03434G0,7523,4360805
1012 07 0033G1,09,660135
1012 07 004 4G1,010,875165
1012 07 0055G1,011,585195
1012 07 0077G1,012,4115230
1012 07 01212G1,016,6195405
1012 07 01818G1,019,4265590
1012 07 02424G1,022,4325710
1012 07 03030G1,023,5395850
1012 07 03434G1,025,8445945
1012 08 0033G1,510,275165
1012 08 004 4G1,510,995200
1012 08 0055G1,511,8110230
1012 08 0077G1,513,5140310
1012 08 01212G1,517,4250480
1012 08 01818G1,520,5315680
1012 08 02424G1,523,6455880
1012 08 03030G1,525,45701050
1012 08 03434G1,527,06301190
1012 09 0033G2,512,1115240
1012 09 004 4G2,513,2140285
1012 09 0055G2,514,2185330
1012 09 0077G2,515,8240440
1012 09 01212G2,521,0390720
1012 09 01818G2,525,45551000
1012 09 02424G2,529,47501340
1012 09 03030G2,531,58201610
1012 09 03434G2,533,49901650
Top 