background
TR  EN  DE  RU

Products

Back to products list
Birtaş Kablo
Control Cables
BIRTFLEX 552 / YSLY
BIRTFLEX 552-CY / YSLYCY
BIRTFLEX 552-SY / YSLYSY
BIRTFLEX 572
BIRTFLEX 572 CY-JB
BIRTFLEX 572 SY-JB
BIRTFLEX 532 / NLSY
BIRTFLEX 532-CY / NLSCY
BIRTFLEX 555 / HO5VV5-F
(NYSLYÖ-JZ/OZ)
BIRTFLEX 555-CY / HO5VVC4V5-K (NYSLYCYÖ-JZ/OZ)
BIRTFLEX 556 / H05V2V2-F
BIRTFLEX 556-CY (H05V2V2C4V2-K)
BIRTFLEX-EF 655
BIRTFLEX-EF 655-CY
BIRTFLEX-EF 656
BIRTFLEX-EF 656-CY
BIRTFLEX 5511-PUR
BIRTFLEX 5511-C-PUR
BIRTFLEX-EF 6511-PUR
BIRTFLEX-EF 6511-C-PUR
BIRTFLEX-EF 6512-PUR
BIRTFLEX-EF 6512-C-PUR
BIRTFLEX 515
BIRTFLEX 515 CY
BIRTFLEX 515 S/C &
BIRTFLEX 616 S/C
2YSLCY-J
HO5VVH6-F (300/500 V) &
H07VVH6-F (450/750 V)
BIRTFLEX-EF 659-PUR
BIRTFLEX-EF 659-C-PUR
BIRTFLEX 552-C / YSLCY
Product Download Files
Birtaş Kablo - Kumanda Kabloları 2YSLCY-J
Product Data Sheet
Local Quality Certificates
International Quality Certificates
Product Price List
Test Reports
Package Style
Summary Table
Reference Samples
MODERN CARTON
EREGLİ STEEL
ISKENDERUN STEEL
KARABÜK STEEL
MITTAL STEEL-ROMANYA
KASTAMONU ENTEGRE
DURMAZLAR MAKINA
TRAKYA GLSS
CONTROL CABLES
BIRTFLEX 532/NLSY
PVC INSULATED, CONTROL CABLES
Marking

BIRTAS KABLO BIRTFLEX 532 / NLSY 3 x 1.5mm2 1007 08 003 Part no GOST-R CE … mt

Application

These flexible and reduced diameter cables are used in mechanical engineering for instrumentation and control equipment for tooling machinery production lines and flexible applications for free movement without tensile load. These cables are not used for outdoor or underground installation.

Cable Design
ConductorFlexible copper wires, plain; IEC 60228 Class 5, TS/DIN EN 60228 Class 5
InsulationPVC compound , TI2
Core identificationAccording to TS/DIN EN 50334 black cores with white numerals
Lay-upCores laid up in layers of optimum pitch
SeparatorPolyester tape
Outer sheathPVC compound, TM2
Sheath colourRAL 7001,Grey
Technical Data
StandardVDE 0245-201
Insulation resistanceMin. 20 MΩ.km
Rated voltage Uo/U300 / 300V
Test voltage2000 V
Temperature rangeFixed: - 40 oC ~ + 70 oC; Mobile: - 5 oC ~ + 70 oC
Min. bending radiusFixed: 6 x D; Mobile: 15 x D
Flame retardance testIEC 60332-1 & EN 50265-2-1
Cross Section
Part-NumberNo. of Cores x
Cross Section (mm2)
Approx. Outer Diameter (mm)Copper Weight (Kg/km)Approx. Cable Weight (Kg/km)
1007 05 0022x0,504,71030
1007 05 0033x0,505,01435
1007 05 0044x0,505,41945
1007 05 0055x0,505,92455
1007 05 0077x0,507,03475
1007 05 01212x0,508,558115
1007 05 01818x0,5010,287165
1007 05 02525x0,5010,7120225
1007 06 0022x0,755,11433
1007 06 0033x0,755,42240
1007 06 0044x0,755,92950
1007 06 0055x0,756,43665
1007 06 0077x0,757,75095
1007 06 01212x0,759,486140
1007 06 01818x0,7511,5130215
1007 06 02525x0,7513,5180305
1007 07 0022x15,41940
1007 07 0033x15,72950
1007 07 0044x16,33865
1007 07 0055x16,94875
1007 07 0077x18,267115
1007 07 01212x110,1116170
1007 07 01818x111,8173245
1007 07 02525x114,6240350
1007 08 0022x1,56,42950
1007 08 0033x1,56,84370
1007 08 0044x1,57,65885
1007 08 0055x1,58,572115
1007 08 0077x1,59,8101165
1007 08 01212x1,512,0174245
1007 08 01818x1,514,5260375
1007 08 02525x1,517,6360490