Birtaş Kablo
|
|
|
|
|
|
Product Download Files |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Birtaş Kablo - Kumanda Kabloları 2YSLCY-J
Product Data Sheet |
|
Local Quality Certificates |
|
International Quality Certificates |
|
Product Price List |
|
Test Reports |
|
Package Style |
|
Summary Table |
|
|
|
|
|
|
|
|
Referans Örnekleri |
|
|
|
KORUPARK SHOPPING CENTER |
|
|
|
TERRACE FULYA HOUSES |
|
|
|
|
FORUM MERSİN SHOPPING CENTER |
|
|
|
MALTEPE CARREFOUR |
|
|
|
|
AGAOGLU MY WORLD |
|
|
|
UPHILL COURT |
|
|
|
|
|
COAXIAL CABLES |
|
|
|
75 Ohm-RG-PVC-Al-CCS COAXIAL CABLES – 75 Ohm - PVC SHEATHED – CCS (Copper Clad Steel ) Conductor, Aluminium & Copper Clad Aluminium Wire Screened
|
|
| | | | RG 59/ U-4 F (Al) | | | | RG 59/ U-6 F (CCA) | | | | RG 6/ U-4 F (Al) | | | | RG 6/ U-6 F (CCA) | | | | RG 11/ U-4 F (Al) | | | | RG 11/ U-6 F (CCA) |
|
|
|
|
Marking |
|
BIRTAS KABLO COAXİAL RG 59 / U-4-F (Al)(CCS) (PHYSICAL FOAM ) 75 OHM [TSEK] Part no GOST-R CE… … mt.
|
|
|
|
|
Applications |
|
These 75 ohm cables used as connection cable in CATV, CCTV and satellite and common antenna TV systems for which low attenuation is demanded. |
|
|
|
|
Cable Design |
|
Inner Conductor (mm) Ø | | | | 0,80 CCS | | | | 0,80 CCS | | | | 1,0 CCS | | | | 1,0 CCS | | | | 1,63 CCS | | | | 1,63 CCS | |
Insulation (mm) Ø | | | | FPE 3,66 | | | | FPE 3,66 | | | | FPE 4,57 | | | | FPE 4,57 | | | | FPE 7,10 | | | | FPE 7,10 | |
Outer Conductor | | | | AL-PES | | | | Cu-PES | | | | AL-PES | | | | Cu-PES | | | | AL-PES | | | | Cu-PES | |
Braid | | | | %55 Al. | | | | %55 CCA | | | | %55 Al. | | | | %55 CCA | | | | %55 Al. | | | | %55 CCA | |
Outer steath Colour | | | | PVC White | | | | PVC White | | | | PVC Black-Orange | | | | PVC Black-Green | | | | PVC Black-Orange | | | | PVC Black-Green | |
Outer Diameter (mm) | | | | 5,80 | | | | 5,80 | | | | 6,80 | | | | 6,80 | | | | 10,10 | | | | 10,10 | |
Part number | | | | 1303 04 059 | | | | 1303 06 059 | | | | 1303 04 006 | | | | 1303 06 006 | | | | 1303 04 011 | | | | 1303 04 011 | |
|
|
|
|
Technical Data |
|
Impedance (ohm) | | | | 75 ± 3 | | | | 75 ± 3 | | | | 75 ± 3 | | | | 75 ± 3 | | | | 75 ± 3 | | | | 75 ± 3 | |
Propagation velocity ratio | | | | 0,82 | | | | 0,82 | | | | 0,82 | | | | 0,82 | | | | 0,82 | | | | 0,82 | |
Insulation resistance | | | | > 2000 | | | | > 2000 | | | | > 2000 | | | | > 2000 | | | | > 2000 | | | | > 2000 | |
Capacitance (pF/m) | | | | 54 | | | | 54 | | | | 54 | | | | 54 | | | | 54 | | | | 54 | |
Min. Bending Radius (mm) | | | | 10xD | | | | 10xD | | | | 10xD | | | | 10xD | | | | 15xD | | | | 15xD | |
Temperature Range | | | | -40 +70oC | | | | -40 +70oC | | | | -40 +70oC | | | | -40 +70oC | | | | -40 +70oC | | | | -40 +70oC | |
Attenuation (20oC)
100 MHz
200 MHz
400 MHz
600 MHz
800 MHz
1000 MHz
1350 MHz
1750 MHz
2150 MHz | | | | ( dB/100m)
8
11,5
17,1
21,2
23,6
26,6
31,3
35,8
40,3 | | | | ( dB/100m)
7,9
11,3
16,8
20,8
23,2
26,1
30,8
35,3
39,2 | | | | ( dB/100m)
7
9,7
14,1
16,9
19,6
22,4
26,1
29,3
32,4 | | | | ( dB/100m)
6,8
9,5
13,8
16,7
18,9
21,9
25,6
28,5
31,6 | | | | ( dB/100m)
4,6
6,7
8,7
11,2
13,3
14,6
17,8
20,5
23,1 | | | | ( dB/100m)
4,4
6,4
8,5
11,0
12,8
14,3
17,2
19,8
22,0 | |
Flame test | | | | IEC 60332-1 EN 50265-2-1 | | | | IEC 60332-1 EN 50265-2-1 | | | | IEC 60332-1 EN 50265-2-1 | | | | IEC 60332-1 EN 50265-2-1 | | | | IEC 60332-1 EN 50265-2-1 | | | | IEC 60332-1 EN 50265-2-1 | |
Oper. Voltage Test Vol. | | | | 1,1 kV 2,5 kV | | | | 1,1 kV 2,5 kV | | | | 1,3 kV 3,0 kV | | | | 1,3 kV 3,0 kV | | | | 2,0 kV 5,0 kV | | | | 2,0 kV 5,0 kV | |
|
|
|
|
|