VBV & VBV-K PVC INSULATED, INDOOR TYPE TELEPHONE CABLES
Beschriftung
BIRTAS KABLO VBV 50 x 2 x 0.50mm 1403 02 050 TS 2814 Part no GOST-R CE....mt
Anwendung
These twisted pairs cables are used as telephone cables inside the buildings for signal transmision and subscriber distribution purposes. VBV-K has tinned copper conductor which this cable is used especially at humudity places. Additionally these cables are suitable for applications at small bending radius.
Kabel Design
Conductor
Annealed copper conductor, solid; for VBV Tinned copper conductor, solid; for VBV-K
Insulation
PVC compound , IEC 60189-2
Core identification
According to IEC 60189-2
Pair
2 cores twisted to a pair, in different lay-length
Lay-up
Cables up to (included) 10 pairs laid up in layers. 20-100 pairs , are formed with 10 pairs subgroups