background
TR  EN  DE  RU

Kabel Produkte

Zurück zur Produkt Liste
Birtas Kabel - Birtaş – Marktführer von Industrie- und Spezialkabeln bis 1kV in der Türkei
Silikonkabel
SIA & H05S-U
SIAF & H05S-K
SIAF-GL & H05SJ-K
SIMH / SIHF
H05SS-F
SIHF EWKF
H05SS-F EWKF
SIMH-FR FE 180
SIMH-FR/PF FE 180
SIMH-SPEC
H05SC4S-K…(SIMH C1)
H05SSC4S-K…(SIMH C2)
SIMH-GL
SIMH-GLS (GLP)
H05SSQS-K…(SIMH-S)
LISHCSH FE 180–E30/E90
JE-SH(St)SH FE 180-E30/E90 …Bd Z
BUJI CABLE – 7 / 10 kV
BUJI CABLE – 16 / 20 kV
N2GFAF
N2GMH2G
LISH(St)CSH-TIMF SPEC
Downloads
Birtaş Kablo - Kumanda Kabloları 2YSLCY-J
Product Data Sheet
Local Quality Certificates
International Quality Certificates
Product Price List
Test Reports
Package Style
Summary Table
Beispiel Referenzen
EREGLI STEEL
ISKENDERUN STEEL
KARABÜK STEEL
MITTAL STEEL-ROMANYA
COLAKOGLU METALURJİ
KASTAMONU ENTEGRE
SILIKONKABEL
H05SSQS-K (SIMH-S)
HIGH TEMPERATURE, INNER SHEATHED ARMOURED SILICONE
Beschriftung

BIRTAS KABLO H05SSQS-K (SİMH-S) 5 x 0.75mm2 1718 06 005 Part no GOST-R CE....mt

Anwendung

These silicone insulated, with inner sheath and steel wire braided armoured cables are used as mobile connecting cables for equipment where high temperatures can arise as well as for ambient air temperature between -60oC and +180 oC. Also these cables are used in all areas where installation conditions are very difficult and have high mechanical loads e.g in ship building, power plants, cooking plants, glass and ceramic works, foundaries, for high power lighting fixtures etc. The armour above the inner sheath acts as a bedding and protecs the cores from any damage of steel wires. Steel wire braid serves as protection against mechanical traverse loads and act as a magnetic screen against interference. The galvanised steel wires are free of corresion and oxidation.

Kabel Design
ConductorIEC 60228 Class 5, TS/DIN EN 60228 Class 5
Flexible copper wires, plain;
InsulationSilicone rubber compound, EI2
Core identificationAccording to TS HD 308 S2 & VDE 0293-308
Acc. to TS/DIN EN 50334 black cores with
white numerals with green/yellow after 5 cores
Lay-upCores laid up in layers of optimum pitch
Inner SheathSilicone rubber compound, EM9
ArmourBraid of galvanised steel wires, approx. %85 cove
Outer sheathSilicone rubber compound, EM9
Sheath colourOxbrown-red
Technische Daten
StandardVDE 0250, DIN VDE 0282-15 and
TS HD 22.15 S1
(Designed according to)
Insulation resistanceMin. 20 MΩ.km
Temp. at conductor+ 180 oC
Short circuit tempetarure+200oC
Rated voltage300 / 500V
Test voltage2000 V
Temperature rangeSabit: - 60 oC ~ + 180 oC
Esnek: - 25 oC ~ + 180 oC
Min. bending radiusFixed: 4 x D
Mobile: 7,5 x D
Flame retardance testIEC 60332-1 & EN 50265-2-1
IEC 60332-3 & EN 50266-2-4
Insulation integrityIEC 60331 , VDE 0472-814
Querschnitt
Part-NumberNo. of Cores x
Cross Section (mm2)
Approx. Outer Diameter (mm)Copper Weight (Kg/km)Approx. Cable Weight (Kg/km)
1718 06 0022x0.758,81495
1718 06 0033x0.759,322125
1718 06 0044x0.7510,229150
1718 06 0055x0.7510,836170
1718 06 0077x0.7512,150205
1718 07 0022x1.09,319140
1718 07 0033x1.010,029175
1718 07 0044x1.010,438205
1718 07 0055x1.011,448245
1718 07 0077x1.012,367275
1718 08 0022x1.510,329180
1718 08 0033x1.510,843200
1718 08 0044x1.511,658260
1718 08 0055x1.512,872290
1718 08 0077x1.513,6101345
1718 08 01212x1.517,4173435
1718 08 01616x1.519,3231685
1718 08 02424x1.522,43461035
1718 09 0022x2.511,948235
1718 09 0033x2.512,572285
1718 09 0044x2.513,896345
1718 09 0055x2.514,9120405
1718 09 0077x2.515,8168485
1718 09 01212x2.520,2288805
1718 10 0022x413,677325
1718 10 0033x414,8115405
1718 11 0022x616,1116440
1718 10 0044x415,9154460
1718 11 0033x617,0173530
1718 10 0055x417,4192565
1718 12 0022x1019,8192600
1718 11 0044x618,5230615
1718 11 0055x620,4288785
1718 12 0033x1021,4288830
1718 12 0044x1023,5384965