background
TR  EN  DE  RU

Kabel Produkte

Zurück zur Produkt Liste
Birtas Kabel - Birtaş – Marktführer von Industrie- und Spezialkabeln bis 1kV in der Türkei
Instrumentenkabel BS 5308
RE-2Y(St)Y-fl-MP
RE-2Y(St)Y-fl-PIMF
RE-2Y(St)Y-fl
RE-2Y(St)Y-fl-TIMF
RE-2Y(St)2YSWAY-fl-MP
RE-2Y(St)2YSWAY-fl-PIMF
RE-2Y(St)2YSWAY-fl
RE-2Y(St)2YSWAY-fl-TIMF
RE-Y(St)Y-fl
RE-Y(St)Y-fl-MP
RE-Y(St)Y-PIMF
RE-Y(St)YSWAY-fl
RE-Y(St)YSWAY-fl-MP
RE-Y(St)YSWAY-PIMF
RE-2Y(St)H & RE-2X(St)H-MP
RE-2Y(St)H & RE-2X(St)H
RE-2Y(St)H-PIMF & RE-2X(St)H-PIMF
RE-2Y(St)H-TIMF & RE-2X(St)H-TIMF
RE-2Y(St)HSWAH & RE-2X(St)HSWAH
RE-2Y(St)HSWAH &
RE-2X(St)HSWAH-MP
RE-2Y(St)HSWAH-PIMF &
RE-2X(St)HSWAH-PIMF
RE-2Y(St)HSWAH-TIMF &
RE-2X(St)HSWAH-TIMF
Downloads
Birtaş Kablo - Kumanda Kabloları 2YSLCY-J
Product Data Sheet
Local Quality Certificates
International Quality Certificates
Product Price List
Test Reports
Package Style
Summary Table
Beispiel Referenzen
MODERN CARTON
TÜPRAS
DOLPHIN PROJECT
ISKENDERUN STEEL
COLAKOGLU METALURJİ
PASABAHCE GLASS
INSTRUMENTENKABEL BS5308
RE-Y(St)Y-fl
INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 1
MULTİ-CORE, PVC INSULATED, COLLECTİVE SCREENED, PVC SHEATHED
Beschriftung

BIRTAS KABLO RE-2Y(St)Y-fl 3 x 0.75mm2 1609 06 003 BS 5308 Part no GOST-R CE....mt

Anwendung

These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits.

Kabel Design
ConductorPlain annealed copper wire, BS 6360
0,50 mm2 and 0,75 mm2 flexible, or
1,5 mm2 stranded
InsulationPVC compound, TI1, BS 6746
Core identificationUp to 40 cores; yellow with black numbers and
word printed (1-40), (10,TEN); up to 80 cores;
black with yellow numbers and word printed
(1-40), (10,TEN)
Lay-upCores laid up in layers of optimum pitch
SeparatorPolyester tape
ScreenAL-PES tape over tinned copper drain wire 0,50 mm2
Outer sheathPVC comp., flame retardant; TM1, BS 7655
Sheath colourRAL 9005, Black
Technische Daten
StandardBS 5308 Part 2 Type 1
Insulation thickness0,50mm2 : 0,60mm
0,75mm2 : 0,60mm
1,50mm2 : 0,60mm
Conductor class, BS 63600,50mm2 : Class 5
0,75mm2 : Class 5
1,5mm2 : Class 2
Conductor resistance0,50mm2 : 39,0 Ω/km
0,75mm2 : 26,0 Ω/km
1,5mm2 : 12,1 Ω/km
Insulation resistanceMin. 25 MΩ.km
Mutual Capacitancemax. 250 pF/m
Capacitance unbalance(1 kHz) : max. 450 pF/250 m
L / R (ratio) (max.)0,50mm2 : 25 µH/Ω
0,75mm2 : 25 µH/Ω
1,5mm2 : 40 µH/Ω
Rated voltage300/500V
Test voltageUrms core-core : 1000 V
Urms core-screen : 1000 V
Temperature rangeoperation : - 40 oC ~ + 70 oC
ınstallation : - 5 oC ~ + 50 oC
Min. bending radius6 x D
Flame retardance testIEC 60332-1 & BS EN 60332-1
Querschnitt
Part-NumberNo. of Cores x
Cross Section (mm2)
Approx. Outer Diameter (mm)Copper Weight (Kg/km)Approx. Cable Weight (Kg/km)
1609 05 0022x0,507,01450
1609 05 0033x0,507,31860
1609 05 0044x0,507,92370
1609 05 0066x0,509,333100
1609 05 01010x0,5011,952155
1609 05 02020x0,5014,9100265
1609 05 04040x0,5020,1196480
1609 05 08080x0,5026,3388910
1609 06 0022x0,757,31860
1609 06 0033x0,757,72670
1609 06 0044x0,758,33380
1609 06 0066x0,759,947120
1609 06 01010x0,7512,776195
1609 06 02020x0,7516,0148340
1609 06 04040x0,7521,7292625
1609 06 08080x0,7528,55801180
1609 45 0022x1,58,33390
1609 45 0033x1,58,947105
1609 45 0044x1,59,762135
1609 45 0066x1,511,790190
1609 45 01010x1,514,7148300
1609 45 02020x1,518,7292540
1609 45 04040x1,524,65801025
1609 45 08080x1,533,611561950
Zum Seitenanfang 
Copyright © Etabir Birlesik Kablo Sanayi ve Ticaret A.S. - 2012. All rights reserved. design: plusmax