background
TR  EN  DE  RU

Kabel Produkte

Zurück zur Produkt Liste
Birtas Kabel - Birtaş – Marktführer von Industrie- und Spezialkabeln bis 1kV in der Türkei
Halogenfreie Telefonkabel
HBH & HBH-K
HBAPH & HBAPH-K
HDH & HDH-K
PDH & PDH-K
J-HH…Bd
J-H(St)H…Bd
J-HH…Lg
J-H(St)H…Lg
J2Y(St)H...Bd
PD-PAH
SHDSH-FR FE180
J-H(St)H...Bd BMK
Downloads
Birtaş Kablo - Kumanda Kabloları 2YSLCY-J
Product Data Sheet
Local Quality Certificates
International Quality Certificates
Product Price List
Test Reports
Package Style
Summary Table
Beispiel Referenzen
ISTINYE PARK SHOPPING CENTER
KORUPARK SHOPPING CENTER
FORUM MERSİN SHOPPING CENTER
CEPA SHOPPING CENTER
KANYON SHOPPING CENTER
ISTANBUL TEKSTİLKENT
HALOGENFREIE TELEFONKABEL
J-H(St)H Lg
HALOGEN-FREE FIRE ALARM INSTALLATION CABLE
Beschriftung

BIRTAS KABLO J-H(St)H ….lg 1 x 2 x 1.38mm² 1951 08 001 FIRE ALARM VDE 0815 Part no GOST-R CE … mt

Anwendung

These halogen-free cables are used for fire alarm systems, signal and data communications as an fixed indoor installations. And also screen provides protection against external pulses . These cables are used at schools, airpots, hospitals, etc. and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low.

Kabel Design
ConductorPlain copper conductor, solid
InsulationHFFR compound, HI2 , VDE 0207-23
Core identificationVDE 0815
* Cables with 2 pairs laid up as a star quad:
PairPairs laid up in layers of optimum pitch
Lay-upStar quads, each 5 star quads stranded in a
units, each unit laid up in layers
SeparatorPolyester tape
ScreenTinned Cu drain wire under the AL-PES tape
Drain wire;
Phi: 0,40 mm ≤10 pairs
Phi: 0,60 mm > 10 pairs
Upon requst drain wire dimension
Outer sheathHFFR kompound, HM2, VDE 0207-24
HFFR: Halogen-free flame retardant
Sheath colourRAL 3000, Red
Technische Daten
StandardVDE 0815 (Designed according to)
Conductor resistance (loop)0,60 mm = 65 Ω/km
0,80 mm = 36 Ω/km
1,00 mm = 43,8 Ω/km
1,38 mm = 23,0 Ω/km
Insulation resistanceMin. 100 MΩ.km
Mutual CapacitanceMax. 100 nF/km
This value may be exceeded by 20% by cables with up to 4 pairs
Capacity UnbalancedMax. 300 pF / 100mt
20% of the values, at least one value up to 500 pF permitted
Operating voltageMax. 300 V
Test voltage Core / core : 800 V / 1000 V
Temperature rangeFixed: - 30 oC ~ + 70 oC
Mobile: - 5 oC ~ + 50 oC
Min. bending radius7,5xD
Flame testIEC 60332-3 & TS/DIN EN 50266-2-4
Smoke density testIEC 61034-2 & TS/DIN EN 61034-2
Halogen-free properties testIEC60754-1/2 & TS/DIN EN 50267-2
Querschnitt
Part-NumberNo. of Cores x
Cross Section (mm2)
Approx. Outer Diameter (mm)Copper Weight (Kg/km)Approx. Cable Weight (Kg/km)
1951 03 0011x2x0,604,9835
1951 03 0022x2x0,605,21545
1951 03 0033x2x0,606,11955
1951 03 0044x2x0,606,62560
1951 03 0066x2x0,607,33680
1951 03 0088x2x0,607,847100
1951 03 01010x2x0,609,059125
1951 04 0011x2x0,805,61440
1951 04 0022x2x0,806,52555
1951 04 0033x2x0,808,13480
1951 04 0044x2x0,808,644100
1951 04 0066x2x0,8010,566135
1951 04 0088x2x0,8011,585165
1951 04 01010x2x0,8012,8108225
1951 06 0011x2x16,52250
1951 06 0022x2x18,03770
1951 06 0033x2x19,752110
1951 06 0044x2x111,067140
1951 06 0066x2x113,197195
1951 06 0088x2x114,3127250
1951 06 01010x2x115,9157300
1951 08 0011x2x1,387,84375
1951 08 0022x2x1,386,670120
1951 08 0033x2x1,3812,2100180
1951 08 0044x2x1,3813,4129220
1951 08 0066x2x1,3816,2187325
1951 08 0088x2x1,3818,4244415
1951 08 01010x2x1,3819,8302485