background
TR  EN  DE  RU

Kabel Produkte

Zurück zur Produkt Liste
Birtas Kabel - Birtaş – Marktführer von Industrie- und Spezialkabeln bis 1kV in der Türkei
Halogenfreie Datenkabel FE180
LIHH FE180 E30/E90
LIHCH FE180 E30/E90
LIH(St)H FE180 E30/E90
LIH(St)CH FE180 E30/E90
J-H(St)H…Lg FE180 E30/E90
JE-H(St)H…Bd Z FE180 E30/E90
JE-H(St)HRH…Bd Z FE180 E30/E90
FR-SH–FIREZERO-MULTICORE…
BS 7629-1…300/500 V
FR-SH–FIREZERO-MULTICORE…
BS 7629-1…300/500 V (ENHANCED)
FR-SHSWAH–FIREZERO-MULTICORE…
BS 7629-1…300/500 V
FR-STH–FIREZERO-MULTIPAIR…
BS 7629-2…300/500 V
FR-STHSWAH–FIREZERO-MULTIPAIR…
BS 7629-2…300/500 V
SİLİKON KOAKSİYEL KABLO - FE180
Downloads
Birtaş Kablo - Kumanda Kabloları 2YSLCY-J
Product Data Sheet
Local Quality Certificates
International Quality Certificates
Product Price List
Test Reports
Package Style
Summary Table
Beispiel Referenzen
ISTINYE PARK SHOPPING CENTER
KORUPARK SHOPPING CENTER
FORUM MERSİN SHOPPING CENTER
CEPA SHOPPING CENTER
KANYON SHOPPING CENTER
ISTANBUL TEKSTILKENT
HALOGENFREIE DATENKABEL FE180
LIH(St)H FE180 E30/E90
HALOGEN-FREE SCREENED DATA CABLES
Beschriftung

BIRTAS KABLO LIH(St)H FE180 E30/E 90 7 x 0.22mm2 1918 02 007 / Ex PROOF TS 3164 IEC 60331 Part no GOST-R CE ... mt.

Anwendung

These cables fields of use are fire proof and halogen free cables which, on the basis of a fixed operating mode, can continue with the supply of a power for a period of 180 minutes under the existing fire conditions (at a temperature of 750OC and under the flames ). Also these cables shall satify EN50200 test which is a fire resistant with mechancal shock test (under the conditions at 842oC and mechenical shock) by the classes PH15-PH30-PH60-PH90. And also the test of DIN 4102-12, E30 and E90 which is a sysyem test with all components and cables to satisfy the system circuit integrity. These halogen-free screened flexible control and connecting cables are used in instrumentation and control engineering; in industrial electronics, computers,security systems information and transmission systems office machines; data transmission cables for voice frequncy transmission. And also screen provides protection against external pulses. These cables are used at schools, airpots, hospitals, etc. and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. These cables are not intended for outdoor or underground installation.

Kabel Design
ConductorFlexible copper wires, plain;
IEC 60228 Class 5, TS/DIN EN 60228 Class 5
InsulationHalogen-free elastomer comp., EN 50290-2-26
Core identificationAccording to DIN 47100
Lay-upCores laid up in layers of optimum pitch
SeparatorPolyester tape
WrappingFiber glass textile tape
ScreenWith drain wire under the AL-PES tape
Outer sheathHFFR compound, HM4, VDE 0207-24
HFFR: Halogen-free flame retardant
Sheath colourRAL 2003, Orange
Technische Daten
Temperature rangeFixed: - 30 oC ~ + 70 oC
Mobile: - 5 oC ~ + 50 oC
Min. bending radiusFixed: 6 x D
Mobile: 15 x D
Smoke density testIEC 61034-2 & TS/DIN EN 61034-2
Halogen-free properties testIEC60754-1/2 & TS/DIN EN 50267-2
Flame testIEC 60332-3 & TS/DIN EN 50266-2-4
Insulation integrityIEC 60331 , VDE 0472-814
Fire resis. with mech. ShockDIN EN 50200; PH30-PH60-PH 90
System circuit integrityDIN 4102-12; E30 & E90
StandardVDE 0812 & VDE 0814 & VDE 0245
Insulation resistanceMin. 50 MΩ.km
Mutual Capacitanced/d-c/c 0,22 mm2 : max. 120 pF/m
d/d-c/c ≥ 0,25 mm2 : max. 150 pF/m
d/e-c/s 0,22 mm2 : max. 240 pF/m
d/e-c/s ≥ 0,25 mm2 : max. 270 pF/m
Inductance~ 0,67 Mh/km
Impedance~ 80 MΩ
Rated voltage0,22 mm2 : 350 V (for peak voltage)
≥0,25 mm2 : 500V
Uo/U ≥0,50 mm2 :300/500V
Test voltage0,22 mm2 : 1200 V
≥0,25 mm2 1500 V
≥0,50 mm2 2000 V
Querschnitt
Part-NumberNo. of Cores x
Cross Section (mm2)
Approx. Outer Diameter (mm)Copper Weight (Kg/km)Approx. Cable Weight (Kg/km)
1918 02 0022x0,224,4723
1918 02 0033x0,224,6927
1918 02 0044x0,225,01135
1918 02 0055x0,225,31442
1918 02 0066x0,225,91645
1918 02 0077x0,225,91850
1918 02 01010x0,226,92565
1918 02 01212x0,227,43075
1918 02 01414x0,227,93880
1918 04 002 2x0,344,6932
1918 04 0033x0,345,11335
1918 04 0044x0,345,31550
1918 04 0055x0,345,91955
1918 04 0066x0,346,32260
1918 04 0077x0,346,32570
1918 04 01010x0,348,13485
1918 04 01212x0,348,940110
1918 04 01414x0,349,247130
1918 05 0022x0,505,41340
1918 05 0033x0,505,71745
1918 05 0044x0,506,12460
1918 05 0055x0,506,62865
1918 05 0066x0,507,33275
1918 05 0077x0,507,33785
1918 05 0088x0,508,14295
1918 05 01010x0,509,251115
1918 05 01212x0,5010,060150
1918 05 01414x0,5010,669170
1918 05 01616x0,5011,578190
1918 05 02020x0,5012,696250
1918 05 02525x0,5014,1120290
1918 06 0022x0,756,02055
1918 06 0033x0,756,42665
1918 06 0044x0,757,03375
1918 06 0055x0,757,64190
1918 06 0066x0,758,148100
1918 06 0077x0,758,155115
1918 06 0088x0,759,063135
1918 06 01010x0,7510,074160
1918 06 01212x0,7510,689180
1918 06 01414x0,7511,1103220
1918 06 01616x0,7512,4118240
1918 06 02020x0,7513,1145305
1918 06 02525x0,7514,8180360
1918 07 0022x1,06,32955
1918 07 0033x1,06,74075
1918 07 0044x1,07,24690
1918 07 0055x1,08,255110
1918 07 0066x1,08,565125
1918 07 0077x1,08,575135
1918 07 0088x1,09,684150
1918 07 01010x1,011,0100190
1918 07 01212x1,012,5120230
1918 07 01414x1,012,1135250
1918 07 01616x1,012,8155295
1918 07 02020x1,014,3195355
1918 07 02525x1,015,9235440
1918 08 0022x1,57,04280
1918 08 0033x1,57,455100
1918 08 0044x1,57,968125
1918 08 0055x1,58,881150
1918 08 0066x1,59,795165
1918 08 0077x1,59,7109200
1918 08 0088x1,511,2121225
1918 08 01010x1,512,5150260
1918 08 01212x1,513,0175315
1918 08 01414x1,514,3202360
1918 08 01616x1,515,0229395
1918 08 02020x1,516,8282480
1918 08 02525x1,518,6345615
Zum Seitenanfang 
Copyright © Etabir Birlesik Kablo Sanayi ve Ticaret A.S. - 2012. All rights reserved. design: plusmax