|
Birtas Kabel - Birtaş – Marktführer von Industrie- und Spezialkabeln bis 1kV in der Türkei
|
|
|
|
|
|
Downloads |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Birtaş Kablo - Kumanda Kabloları 2YSLCY-J
Product Data Sheet |
|
Local Quality Certificates |
|
International Quality Certificates |
|
Product Price List |
|
Test Reports |
|
Package Style |
|
Summary Table |
|
|
|
|
|
|
|
|
Beispiel Referenzen |
|
|
|
KORUPARK SHOPPING CENTER |
|
|
|
TERRACE FULYA HOUSES |
|
|
|
|
FORUM MERSİN SHOPPING CENTER |
|
|
|
MALTEPE CARREFOUR |
|
|
|
|
AGAOGLU MY WORLD |
|
|
|
UPHILL COURT |
|
|
|
|
|
KOAXIALKABEL |
|
|
|
75 Ohm-RG-PVC-Cu COAXIAL CABLES – 75 Ohm - PVC SHEATHED
|
|
| | | | RG 59/ U-4 F | | | | RG 59/ U-6 F | | | | RG 6/ U-4 F | | | | RG 6/ U-6 F | | | | RG 11/ U-4 F | | | | RG 11/ U-6 F |
|
|
|
|
Beschriftung |
|
BIRTAS KABLO COAXİAL RG 59 / U-4-F (PHYSICAL FOAM ) 75 OHM [TSEK] Part no GOST-R CE….… mt.
|
|
|
|
|
Anwendung |
|
These 75 ohm cables used as connection cable in CATV, CCTV and satellite and common antenna TV systems for which low attenuation is demanded. |
|
|
|
|
Kabel Design |
|
Inner Conductor (mm) Ø | | | | 0,80 Cu | | | | 0,80 Cu | | | | 1,0 Cu | | | | 1,0 Cu | | | | 1,63 Cu | | | | 1,63 Cu | |
Insulation (mm) Ø | | | | FPE 3,66 | | | | FPE 3,66 | | | | FPE 4,57 | | | | FPE 4,57 | | | | FPE 7,10 | | | | FPE 7,10 | |
Outer Conductor | | | | AL-PES | | | | Cu-PES | | | | AL-PES | | | | Cu-PES | | | | AL-PES | | | | Cu-PES | |
Braid | | | | %55 SnCu | | | | %55 SnCu | | | | %55 SnCu | | | | %55 SnCu | | | | %55 SnCu | | | | %55 SnCu | |
Outer steath Colour | | | | PVC White | | | | PVC White | | | | PVC Black-Orange | | | | PVC Black-Green | | | | PVC Black-Orange | | | | PVC Black-Green | |
Outer Diameter (mm) | | | | 5,80 | | | | 5,80 | | | | 6,80 | | | | 6,80 | | | | 10,10 | | | | 10,10 | |
Part number | | | | 1301 04 059 | | | | 1301 06 059 | | | | 1301 04 006 | | | | 1301 06 006 | | | | 1301 04 011 | | | | 1301 04 011 | |
|
|
|
|
Technische Daten |
|
Attenuation (20oC) 100 MHz 200 MHz 400 MHz 600 MHz 800 MHz 1000 MHz 1350 MHz 1750 MHz 2150 MHz | | | | (dB/100m) 8 11,5 17,1 21,2 23,6 26,6 31,3 35,8 40,3 | | | | (dB/100m) 7,9 11,3 16,8 20,8 23,2 26,1 30,8 35,3 39,2 | | | | (dB/100m) 7 9,7 14,1 16,9 19,6 22,4 26,1 29,3 32,4 | | | | (dB/100m) 6,8 9,5 13,8 16,7 18,9 21,9 25,6 28,5 31,6 | | | | (dB/100m) 4,6 6,7 8,7 11,2 13,3 14,6 17,8 20,5 23,1 | | | | (dB/100m) 4,4 6,4 8,5 11,0 12,8 14,3 17,2 19,8 22,0 | |
Flame test | | | | IEC 60332-1 EN 50265-2-1 | | | | IEC 60332-1 EN 50265-2-1 | | | | IEC 60332-1 EN 50265-2-1 | | | | IEC 60332-1 EN 50265-2-1 | | | | IEC 60332-1 EN 50265-2-1 | | | | IEC 60332-1 EN 50265-2-1 | |
Oper. Voltage Test Vol. | | | | 1,1 kV1 2,5 kV | | | | 1,1 kV1 2,5 kV | | | | 1,3 kV1 3,0 kV | | | | 1,3 kV1 3,0 kV | | | | 2,0 kV1 5,0 kV | | | | 2,0 kV1 5,0 kV | |
Min. Bending Radius (mm) | | | | 10xD | | | | 10xD | | | | 10xD | | | | 10xD | | | | 15xD | | | | 15xD | |
Temperature Range | | | | -40 +70oC | | | | -40 +70oC | | | | -40 +70oC | | | | -40 +70oC | | | | -40 +70oC | | | | -40 +70oC | |
Impedance (ohm) | | | | 75 ± 3 | | | | 75 ± 3 | | | | 75 ± 3 | | | | 75 ± 3 | | | | 75 ± 3 | | | | 75 ± 3 | |
Propagation velocity ratio | | | | 0,82 | | | | 0,82 | | | | 0,82 | | | | 0,82 | | | | 0,82 | | | | 0,82 | |
Insulation resistance | | | | > 2000 | | | | > 2000 | | | | > 2000 | | | | > 2000 | | | | > 2000 | | | | > 2000 | |
|
|
|
|
|