75 Ohm-RG-HFFR COAXIAL CABLES – 75 Ohm - HFFR (Halogen-Free Flame Retardant) SHEATHED
RG 59/ U-4 F HF RG 59/ U-6 F HF RG 6/ U-4 F HF RG 6/ U-6 F HF RG 11/ U-4 F HF RG 11/ U-6 F HF
Beschriftung
BIRTAS KABLO COAXİAL RG 59 / U-4-F-HF (PHYSICAL FOAM ) 75 OHM Part no GOST-R CE… … mt.
Anwendung
These 75 ohm cables used as connection cable in CATV, CCTV and satellite and common antenna TV systems for which low attenuation is demanded. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire.
Kabel Design
Inner Conductor (mm) Ø 0,80 Cu 0,80 Cu 1,0 Cu 1,0 Cu 1,63 Cu 1,63 Cu
Insulation (mm) Ø FPE
3,66 FPE
3,66 FPE
4,57 FPE
4,57 FPE
7,10 FPE
7,10
Outer Conductor AL-PES CU-PES AL-PES CU-PES AL-PES CU-PES
Braid %60
SnCu %60
Cu %55
SnCu %55
Cu %60
SnCu %60
Cu
Outer steath Colour HFFR
Black HFFR
Black HFFR
Black HFFR
Black HFFR
Black HFFR
Black
Outer Diameter (mm) 5,80 5,80 6,80 6,80 10,10 10,10
Part number 1305 04 059 1305 06 059 1305 04 006 1305 06 006 1305 04 011 1305 04 011
Technische Daten
Min. Bending Radius (mm) 10xD 10xD 10xD 10xD 15xD 15xD
Temperature Range -40 +70oC -40 +70oC -40 +70oC -40 +70oC -40 +70oC -40 +70oC
Impedance (ohm) 75 ± 3 75 ± 3 75 ± 3 75 ± 3 75 ± 3 75 ± 3
Propagation velocity ratio (v/c) 0,82 0,82 0,82 0,82 0,82 0,82
Insulation resistance (Mohm.km) > 2000 > 2000 > 2000 > 2000 > 2000 > 2000
Capacitance (pF/m) 54 54 54 54 54 54
Attenuation (20oC)
100 MHz
200 MHz
400 MHz
600 MHz
800 MHz
1000 MHz
1350 MHz
1750 MHz
2150 MHz ( dB/100m)
8
11,5
17,1
21,2
23,6
26,6
31,3
35,8
40,3 ( dB/100m)
11,3
16,8
20,8
23,2
26,1
30,8
35,3
39,2 ( dB/100m)
7
9,7
14,1
16,9
19,6
22,4
26,1
29,3
32,4 ( dB/100m)
6,8
9,5
13,8
16,7
18,9
21,9
25,6
28,5
31,6 ( dB/100m)
4,6
6,7
8,7
11,2
13,3
14,6
17,8
20,5
23,1 ( dB/100m)
4,4
6,4
8,5
11,0
12,8
14,3
17,2
19,8
22,0
Flame test IEC 60332-3 EN 50266-2-4 IEC 60332-3 EN 50266-2-4 IEC 60332-3 EN 50266-2-4 IEC 60332-3 EN 50266-2-4 IEC 60332-3 EN 50266-2-4 IEC 60332-3 EN 50266-2-4
Halogen-free test IEC 60754-2 EN 50266-2 IEC 60754-2 EN 50266-2 IEC 60754-2 EN 50266-2 IEC 60754-2 EN 50266-2 IEC 60754-2 EN 50266-2 IEC 60754-2 EN 50266-2
Smoke Density IEC 61034-2 EN 61034-2 IEC 61034-2 EN 61034-2 IEC 61034-2 EN 61034-2 IEC 61034-2 EN 61034-2 IEC 61034-2 EN 61034-2 IEC 61034-2 EN 61034-2
Oper. Voltage Test Vol. 1,1 kV 2,5 kV 1,1 kV 2,5 kV 1,3 kV 3,0 kV 1,3 kV 3,0 kV 2,0 kV 5,0 kV 2,0 kV 5,0 kV